Analysis and Exclusion of Non-fault Phenomena
■ Fog condensation on the outside surface of the ice maker
- When the air humidity is high, this phenomenon will occur, just
wipe it dry.
■ Abnormal noise ("hiss" "whirr" "tick" "whine")
- When the refrigeration system is working, there will be a "hissing"
sound when the refrigerant flows in the pipeline.
- When the refrigeration system is working, there will be a slight
"whirr" sound when the fan rotates.
- When the water tank rotates to the ice-shedding position, there
will be a "tick" sound of the solenoid valve opening/closing.
- When the water is filled inside, there will be a "whining" sound of
the pump pumping water.
- The above conditions are normal phenomena when the ice maker
is working.
Analysis and Exclusion of Special Phenomena
LED screen no
The power plug is not
display; no sound
plugged in properly;
when pressing
power failure; control
buttons
system is broken
The drain plug is not
plugged; the internal
Water seepage;
water circulation pipeline
water leak
is poorly connected or
damaged
The water volume is too
low; water circulation
There is water in
vent in storage area
the storage area
blocked and Failed to fill
but still indicating
small tank; failure of
water shortage
internal water circulation
and its detection system
18
Plug in the power socket; Check
for power failure; need a
professional personnel to check
and maintain control system
Plug in the stopper; need
professionals to check and
maintain the internal water
circulation pipeline
Add water according to the
water filling instructions; remove
foreign objects from the
circulation water Outlet of the
water storage area; need
professionals to check and
maintain the internal water
circulation and its detection
system
Ice storage area
Ice cubes or foreign
has no ice or small
objects block the signal
amount of ice, but
transmission of
indicating full ice
photoelectric sensor ;
photoelectric sensor in
failure
Display alarm and
The temperature sensor
E1 icon (in this
wire is disconnected or
case, ice can still
broken
be made)
Display alarm and
The temperature sensor
E2 icon
is short-circuited or the
detected temperature is
too high
The ice making
The refrigeration system
mode operates
is not running stably; the
normally, no ice is
ventilation grill is blocked;
made or a small
the fan is not working or
amount of ice is
the refrigeration system
made
is in failure
Abnormal noise
Resonance; internal
motion; noise of control
devices
Displayed icons
LED screen broken
missing
Disposal
To protect the environment, waste electrical products should not be
disposed of together with household garbage.
If you no longer use this product and need to dispose of it, please place
it in a special recycling and storage place in accordance with the local
regulations on the disposal of flammable equipment. If you don't
understand, please consult your local government or retailer for
recycling recommendations.
Remove ice cubes and foreign
objects; need professionals to
check and replace the
photoelectric sensor
Professionals are needed to
check and replace the
temperature sensor
Check whether the ventilation
grid is blocked; professional
personnel are required to
inspect and repair
Continue to observe; remove
the items near the ventilation
grille and clean the dust
accumulation; need
professionals to check and
repair
When making ice, the operation
of the internal electric
components will generate
vibration, to ensure that no other
items near the ice maker are
affected by vibration, the
product will resonate and cause
noise; need professionals to
check and repair
Professionals are needed to
check and replace the operation
panel