THERMO TECHNICAL CHARACTERISTICS
Thermal power output
Yield / Effi ciency
Emissions CO 13% O
2
Fume temperature
Fuel consumption
Hopper capacity
Draught
Autonomy
Heatable volume *
Smoke outlet pipe diameter (male)
Air intake pipe diameter (male)
Weight including packaging
TECHNICAL DATA FOR SIZING THE FLUE which must, in any case, comply with the guidelines of
this sheet and the installation rules for each product
Thermal power output
Temperature of fumes on exit from the discharge pipe
Minimum draught
Fume fl ow capacity
* The heatable room dimensions are calculated on the basis of home insulation in compliance with Italian law 10/91, and subse-
quent changes together with an expected heat output of 33 Kcal/m³ per hour.
ELECTRICAL CHARACTERISTICS
Power supply
Average power consumption
Power consumption during ignition
Remote control frequency
Protection on electronic circuit board
N.B.
1) keep in mind that external devices can cause interference to the operation of the circuit board.
2) warning: activity on live components, maintenance and/or checks must be carried out by qualifi ed personnel.
(before carrying out any maintenance, disconnect the appliance from the mains electricity)
3) In case of problems with the electrical grid, consult an electrician to evaluate the installation of a UPS of at least 800
Vac. Power variations greater than 10% can cause problems for the product.
The above data are indicative and are those resulting during certifi cation on the part of the notifi ed body.
EDILKAMIN s.p.a. reserves the right to change the products at its discretion without notice.
SAFETY DEVICES
• THERMO COUPLING:
located on the smoke exhaust, detects the temperature. On the basis of the parameters set, check the ignition, working and turn-off
phases.
• VACUUM GAUGE:
Positioned on the smoke extractor, which detects the vacuum value (compared to the installation environment) in the combustion
chamber
• SAFETY THERMOSTAT:
Intervenes when the temperature within the insert is too high. Blocks pellet loading causing the insert to turn off.
• ROOM TEMP. DETECTION PROBE:
located on the remote control. Alternatively it can be connected up to the electronic board inside the insert.
GENERAL INFORMATION
according to EN 14785)
Nominal power
10
90
190
120
2,4
11
12 - 5
3
260
80
40
144
Nominal power
10
144
0 - 5
5,2
230 Vac +/- 10% 50 Hz
120 - 150 W
400 W
2,4 GHz
Fusibile 2AT, 250 Vac 5x20
- 37
-
Reduced power
3
kW
90
%
198
mg/m
80
°C
0,7
kg/h
kg
10 - 3
Pa
11
hours
3
m
mm
mm
kg
Reduced power
3
kW
96
°C
Pa
3
g/s
3