9. Specifications

9. Specifications
Models OLS-C01, OLS-C02, OLS-C04 and OLS-C05
EN

General data

Measuring accuracy
Mounting position
Visual indication of the
switching status

Design data

Responsiveness
Medium temperature
Ambient temperature
Operating pressure

Electrical data

Power supply
Max. current supply
Output
Switching function
Switching current
Ingress protection
Number of switch points
20
WIKA operating instructions optoelectronic level switches, models OLS-C
±0.5 mm
as required
1 LED (not for model OLS-C02)
preset
Models OLS-C01, OLS-C02: -30 ... +100 °C
Model OLS-C04: -40 ... +100 °C
Model OLS-C05: -40 ... +150 °C
Models OLS-C01, OLS-C02: -25 ... +70 °C
Model OLS-C04: -30 ... +70 °C
Model OLS-C05: -30 ... +80 °C
0 ... 2.5 MPa (0 ... 25 bar)
Model OLS-C04: 0 ... 4 MPa (0 ... 40 bar)
DC 12 ... 32 V
40 mA
PNP transistor, protected against reverse
polarity
Normally open (closed in medium) or normally
closed (open in medium)
200 mA
IP 65
1