9. Specifications
Model OLS-C20
General data
Measuring accuracy
Light source
Ambient light
Mounting position
Visual indication of the switching status
Design data
Medium temperature
Ambient temperature
Pressure range
Materials
Sensor housing
Light guide
Packing
Case
Electrical data
Power supply
Max. current supply
Output
Switching function
Switching current (T
Electrical connection
PVC cable
Connector
Ingress protection
With connector
With cable
WIKA operating instructions optoelectronic level switches, models OLS-C
-30 ... +135 °C
-25 ... +70 °C
0 ... 50 bar
Stainless steel 1.4571
Fused quartz
Graphite/PTFE
Stainless steel 1.4301
DC 24 V, -25 ... +30 %
40 mA
O. C. pnp transistor, short-circuit proof,
current, voltage and power limitation
Normally open (closed in medium) or
normally closed (open in medium)
= 70 °C)
0.5 A
u
3 x 0.14 mm
4-pin series 712, M12
IP 65
IP 66
±0.5 mm
IR light 930 nm
max. 10,000 Lux
as required
green LED
2
EN
21