PEDROLLO DGF/T M/M 8.5 Manual De Uso Y Mantenimiento página 30

Ocultar thumbs Ver también para DGF/T M/M 8.5:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5
6
When DGFIT is energized, there is a STARTING phase lasting 8 seconds, after which there can
be three cases:
1. the inverter enters AUTOMATIC OPERATION, if at the last shutdown it was in automatic
operation.
the inverter is ready to operate even at the first start-up, as ALL PARAMETERS ARE
FACTORY SETTINGS and the only check to be performed is the correct rotation of the
motor for the DGFIT MT models (three-phase motor).
2. the inverter is OUT OF SERVICE, if it had been manually taken out of service at the last
shutdown
3. by pressing the SET key within 8 seconds of the STARTING phase, you enter SELF-
LEARNING MODE (see below)
PARAMETERS SELF-LEARNING (WIZARD)
WIZARD asks in automatic sequence all the necessary
Required parameters are:
-
Language (IT / EN)
-
Number of pumps (1 = single pump, 2/3 = pumping unit)
-
Working pressure
-
Scale of the sensor ( 0-10 / 0-16 / 0-25 / 0-40 bar)
-
Nominal current of the motor (it is suggested to add a margin of 15%)
DESCRIPTION OF THE KEYBOARD
1
2
3
SWITCHING ON
parameters for the complete setting of the inverter.
1- START / STOP button (in
4
7
2- Display
3- Enter / exit arrows to
4- SET button
5- Red LED for connection to
6- Green LED for activation
7- Arrows to scroll through
30
service / out of service)
enter and exit MENUS /
parameters
power (POWER)
(STATUS)
MENUS / parameters

Publicidad

loading

Este manual también es adecuado para:

Dgfit m/m 11Dgfit m/m 16Dgf/t m/t 7Dgfit m/t 10