P_3.5
Keep both pressed for 5 sec
-
Until the operating frequency is greater than the SHUTDOWN FREQUENCY (i.e. there is a
demand for water) the inverter will keep the pump on
-
When the operation frequency falls below the SHUTDOWN FREQUENCY (i.e. the demand
for water has ceased) the inverter will shut down the pump
- In TEST mode it starts and adjusts the pump manually.
- During the TEST it is possible to view the operating parameters (see instructions below)
OFF
3 sec
Definition of the shutdown frequency
Only possible in AUTOMATIC OPERATION mode
****
only possible in OUT OF SERVICE mode (OFF)
BASIC
X 3
To SPEED UP /
SLOW DOWN
the pump
P_3.2
Z 41.0
Current
Set to
minimum flow
work
(min. 5 l/min)
frequency
TEST
TEST
To VIEW the
operation
parameters
F 40
START
/ stop
35
Z 33.6
Shutdown
frequency
START
P_2.2
/ stop
OFF
Confirmation