¢L_.UU
COIN SLIDE OPTION
This option is either SELECTED "ON" or NOTSELECTED "0FE"
Replacement of metercase will beneeded for coin slidemounting.
o. u_
Not Selected"OFE"
d._
Selected"ON."
NOTE: T his option needsto be setto "00" unlessthe
metercasehas beenchangedto accepta coin slide device.
PressDELiCATES button3 consecutivetimes for this
selection.When coin slide mode is selected,set "b." equalto
value of slide in coins. Set "6 xx" (REGULAR CYCLEPRICE)
and "3.xx" (SPECIALCYCLE PRICE)to number of slide
operations.6 01 & 3.01 = 1 slidepush.
NOTE:if the installersets up "CS" on a coin drop model,
it will not register coins.
-> PressPERM.PRESSbutton onceto advanceto next code.
Cnn
J_.uu
ADD COINS OPTION
This option is either SELECTED "ON" or NOTSELECTED "0FE"
This option causesthe customer displayto showthe number
of coins (coin 1) to enter,ratherthan the amount.
cnn
c._
Not Selected"OFE"
C'_l-
c._
Selected"ON."
PressDELiCATES button3 consecutivetimes for this selection.
PN MODELS: T his option is not selectable.
-> PressPERM.PRESSbutton onceto advanceto next code.
If"
I
,__c o
COIN/DEBIT OPTION
II--
I
,a._
Bothcoin anddebit selected.(NOTAVAILABLE)
IF
u._
Coins selected,debit disabled.
PressDELICATES button3 consecutivetimes for this selection.
I
t
,.J.-L=_o
DebitCardselected,coin disabled.Defaultfor PN models,
and for PN operation,must be set as J._d.
PressDELICATES button3 consecutivetimes for this selection.
IC
t
,..i._
EnhancedDebitis self-selected when a Generation2 card
readeris installedinthe dryer.The "Ed" option cannot be
manuallyselectedor deselected. ( NOTAVAILABLE)
-> PressPERM.PRESSbutton onceto advanceto next code.
c_.ju u
PRICE SUPPRESSION OPTION
This option is either SELECTED "ON" ORNOTSELECTED
"0FE" This option causesthe customer displayto show
"AVAILABLE" or "ADD" ratherthan the amount of money
to add. (Usedmainly in debit installations.)
c._
Not Selected"OFE"
o c
Selected"ON." PressDELICATES buttononcefor this selection.
c._
-> PressPERM.PRESSbutton onceto advanceto next code.
_.c c
CLF..AR ESCROW OPTION
This option is either SELECTED "ON" ORNOTSELECTED
"OFE"When selected,money held in escrowfor 30 minutes
without further escrow or cycleactivitywiii be cleared.
r_ t_2_
Selected"ON."
nn
Not Selected"OFE" PressDELiCATES buttononceto deselect
this option.
-> PressPERM.PRESSbutton onceto advanceto next code.
i i n n
HUNDREDTH INCREMENT OFFSET
IU.tU
U
u. u_
This representsthe hundredth incrementprice offset used
in Generation2 (EnhancedDebit)PN models set up with card
reader.Choosefrom 0-4 hundredths by pressingthe WHITES
AND COLORS button. (NOTAVAILABLE)
-> PressPERM.PRESSbutton onceto advanceto next code.
If cycle counter (90C) is selected, the following
is true:
1 00 Represents the number of cycles in HUNDREDS.
1 02 = 200
2 00 Represents the number of cycles in ONES.
2 2,5 = 25
TOTAL CYCLES = 225
This is "VIEW ONLY" and cannot be cleared.
Press the PERM. PRESS button once to advance
to next code.
If money counter (1.0C or 1.C0) is selected, the following is true:
3 00 Currency amount in HUNDREDS.
3 01 = 100.00
4 00 Currency amount in ONES.
4 68 = 68.00
5 00 Currency amount in HUNDREDTHS.
5 7,5 = 00.75
TOTAL = 168.75
END OF SET-UP PROCEDURES
F.X|T FROM
SET=UP MODI:
[] PD MODELS: Reinstall access door.
[] PN MODELS where AA1 plug was removed:
1. Unplug dryer or disconnect power.
2. Open console, reinsert jumper into AA1, close console.
3. Plug in dryer or reconnect power.
[] PN WITH PROGRAMMING SWITCH: Turn key clockwise and
remove.
[] If Service Access Code was used to enter set-up mode: From
Set-up Code 8, press button #1 for 4 seconds, wait 2 minutes
without touching any buttons (without diagnostic modes running),
or power down the dryer, then reapply power.
Manufacturer:
Whirlpool
Corporation,
1300 Marion-Agosta
Rd., Marion, OH 43302,
USA.
EU representatives:
Maytag
UK Ltd., 2 St. Annes Blvd.,
Redhill, RH1 lAX, UK & Bauknecht
Hausgerb_te GmbH,
D-73614
Schorndorf,
Germany
EU - DECLARATION
OF CONFORMITY
_T-
DECLARATION
DE CONFORMITE
_ /,,o,.) BAUKNECIIT
HAUSG[
RA,TE Gmb[l,
D-73614
Schomdorf
_pr entix hq),¢_¢_a,d_WIIIRLPOOL
EUROPE
St]
1-21025 COMERIO
declare under our sole responsibility
that tile pro_l*i
d_,,r
Maytag
MDE25PD
Maytag
MDE25PN
to which
lids
declaration
relates
is in con formii7
with
tile following
stalldard(s)
or other
normative
document(s)
EN 60335-1:2002+A
I+A2+A1
I+AI
2+A13+A
14
EN 60335-2-11:2003+A
]+A2+A
I 1
EN 62233:2008
EN ISO
10472-1:2008
EN ISO
10472-2:2008
EN 55014-1:2006+AI
:2009
EN 55014-2:1997+Corrigend_lm
:1997+A
[ :2001+A2:2008
EN 61000-3-12:2005
EN 61000-3-I
1:2000
following the provisions of Directive(s):
2006/42/EC MACHINERY
I)ll/EC rIVE (_
_J_,,,i __,_.,,_
_;cllornflori; 1 9.10.2011
Franz ttartmann
Karl-Dieter
Klini_ensteln
_U_ _,_a_:
Director PI)(: FC EMEA
Product Approval
_,,,_,,, a.....
GPO, Schorndorf
14