10. Troubleshooting guide
Problem
Motor does not
start.
Motor performance
drops.
Important! For protection, the motor is equipped with a thermal switch which cuts out when
the motor is overloaded and switches on again automatically after a short cooling period.
Anl_GE_CR_30_Li_USA_SPK7.indb 14
Anl_GE_CR_30_Li_USA_SPK7.indb 14
EN
Possible cause
- Safety plug is not inserted.
- Battery is not correctly inserted.
- Motor terminals or capacitor
disconnected.
- Excessive working depth.
- Batteries are empty.
- Soil too hard.
- Tine is heavily worn.
- 14 -
Solution
- Insert the safety plug (see 6.).
- Remove batteries and reinsert
(see 5.).
- By customer service workshop.
- Reduce the working depth.
- Charge batteries (see 5.).
- Correct the working depth.
- Replace cultivator tines.
19.07.2023 11:15:38
19.07.2023 11:15:38