Descargar Imprimir esta página

HIKOKI EC36DA Instrucciones De Manejo página 12

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 79
English
○ Check to see if the intake fi lter cap is loose. If the fi lter
is loose, remove and reinstall the fi lter. (Fig. 3)
4. Attaching hose (sold separetely)
○ Insert the hose into the quick coupler already installed
on the compressor. (Fig. 4)
WARNING
Do not attach any tools to the open end of the hose until
start-up has been completed.
○ Firmly grasp the open end of the hose; hold facing
away from yourself and others.
REMOVAL AND INSTALLATION
METHOD OF BATTERY
○ How to install the battery.
Align the battery with the groove in head cover and slip
it into place.
Always insert it all the way until it locks in place with a
little click. If not, it may accidentally fall out of the tool,
causing injury to you or someone around you. (Fig. 5)
○ How to remove the battery.
Withdraw battery from the head cover while pressing
the latch (2 pcs) of the battery. (Fig. 5)
Before
charging
While
charging
Charge
indicator
lamp
(RED /
BLUE /
Charging
GREEN /
complete
PURPLE)
Overheat
standby
Charging
impossible
Indications of the charge indicator lamp
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(RED)
Lights for 0.5 seconds. Does not light
Blinks
for 1 second. (off for 1 second)
(BLUE)
Lights for 1 second. Does not light
Blinks
for 0.5 seconds. (off for 0.5 seconds)
(BLUE)
Lights
Lights continuously
(BLUE)
Lights continuously
Lights
(GREEN)
(Continuous buzzer sound: about
6 seconds)
Lights for 0.3 seconds. Does not light
Blinks
for 0.3 seconds. (off for 0.3 seconds)
(RED)
Lights for 0.1 seconds. Does not light
for 0.1 seconds. (off for 0.1 seconds)
Flickers
(PURPLE)
(Intermittent buzzer sound: about
2 seconds)
CHARGING
Before using the power tool, charge the battery as follows.
1. Connect the charger's power cord to the
receptacle.
When connecting the plug of the charger to a
receptacle, the charge indicator lamp will blink in red
(At 1- second intervals).
2. Insert the battery into the charger.
Firmly insert the battery into the charger as shown in
Fig. 6 (on page 3).
3. Charging
When inserting a battery in the charger, the charge
indicator lamp will blink in blue.
When the battery becomes fully recharged, the charge
indicator lamp will light up in green. (See Table 1)
(1) Charge indicator lamp indication
The indications of the charge indicator lamp will be
as shown in Table 1, according to the condition of the
charger or the rechargeable battery.
Table 1
12
Plugged into power source
Battery capacity at less than 50%
Battery capacity at less than 80%
Battery capacity at more than 80%
Battery overheated. Unable to
charge. (Charging will commence
when battery cools)
Malfunction in the battery or the
charger

Publicidad

loading