Technical data
Cordless wet/dry dust extractor
Article number
Voltage
Rated power input
Protection class
Container volume (gross)
Net volume (liquid)
A)
Max. vacuum
B)
– Dust extractor
– Turbine
A)
Max. flow rate
B)
– Dust extractor
– Turbine
Dust class
Weight according to EPTA-Pro-
cedure 01:2014
Recommended ambient tem-
perature during charging
Permitted ambient temperature
D)
during operation
and during
storage
Recommended rechargeable
batteries
Recommended chargers
Operating time per battery
charge
A) Measured at 20–25 °C with rechargeable battery
GBA 18V 6.3Ah
B) measured with vacuum hose (13) and curved nozzle (15)
C) Depends on battery in use
D) Limited performance at temperatures <0 °C
Noise/Vibration Information
Noise emission values determined according to
EN 60335‑2‑69.
Typically the A-weighted sound pressure level of the dust ex-
tractor is 79 dB(A). Uncertainty K = 2 dB. The noise level
when working can exceed the volume stated. Wear hearing
protection!
Vibration total values a
(triax vector sum) and uncertainty K
h
determined according to EN 60335‑2‑69:
2
2
a
< 2.5 m/s
, K = 1.5 m/s
.
h
1 609 92A 6PF | (26.07.2021)
Assembly
GAS 18V-10 L
Charging the Battery
3 601 JC6 3..
u
V
18
W
260
IPX4
Note: The battery is supplied partially charged. To ensure
full battery capacity, fully charge the battery in the charger
l
10
before using your power tool for the first time.
l
6
The lithium-ion battery can be charged at any time without
reducing its service life. Interrupting the charging process
hPa
90
does not damage the battery.
The lithium-ion battery is protected against deep discharge
hPa
115
by the "Electronic Cell Protection (ECP)". A protective circuit
switches the cordless dust extractor off when the battery is
l/s
24
drained.
m³/h
86
u
l/s
34
m³/h
122
L
A significantly reduced operating time after charging indic-
ates that the battery has deteriorated and must be replaced.
C)
kg
5.1−6.1
Follow the instructions on correct disposal.
°C
0 to +35
Battery Charge Indicator
When the rechargeable battery is inserted, you can see the
°C
–20 to +50
state of charge of the battery on the battery charge
indicator (4) on the dust extractor. When the rechargeable
battery is removed, you can see this on the battery itself.
GBA 18V...
Battery Charge Indicator on the Dust Extractor
ProCORE18V...
After the dust extractor is switched on, the five green LEDs
GAL 18...
of the battery charge indicator (4) will light up individually
GAX 18...
one after another in ascending and descending order. Then
GAL 36...
the LEDs will indicate the state of charge of the battery (20).
min/Ah
4
Battery Charge Indicator on the Rechargeable Battery
If the rechargeable battery is removed from dust extractor,
its state of charge may be indicated by the green LEDs of the
battery charge indicator on the battery.
Press the button for the battery charge indicator
show the state of charge.
If no LED lights up after pressing the button for the battery
charge indicator, then the battery is defective and must be
replaced.
Battery model GBA 18V...
LEDs
3× continuous green light
2× continuous green light
1× continuous green light
1× flashing green light
Use only the chargers listed in the technical data. Only
these chargers are matched to the lithium-ion battery of
your dust extractor.
Do not continue to press the on/off button after the
dust extractor has automatically switched itself off.
This can damage the battery.
or
to
Capacity
60−100 %
30−60 %
5−30 %
0−5 %