Themaximum permitted l ength forboth
rigidandflexible metal d uctisshown in
thetablebelow.
Number of Rigid D uct
Flexible Duct
90 °Turns
orElbows
0
66ft.
45ft.
(2011cm)
(1372 cm)
1
56 ft.
36 ft.
(1707cm)
(1097 cm)
2
48 ft.
29 ft.
(1463cm)
(884 cm)
3
39 ft.
22 ft.
(1189cm)
(671 cm)
4
3Oft.
16 ft.
(914cm)
(488 cm)
Note:
Side and bottom exhaust installations
have a 90° turn inside the dryer. To
determine maximum exhaust length,
add one 90 °turn to the chart.
More than two 90 ° turns are not
recommended. For best performance,
separate all turns by at least 4 ft. of
straight duct, including distance
between last turn and exhaust hood.
Good
Better
Required
parts
The parts required for the exhaust air
system (elbows, lines, exhaust air
outlets) are not included in standard
delivery of the dryer.
Accessories
The parts required for the exhaust air
system can be obtained from customer
service or your local dealer. Please
follow the installation instructions
supplied with kits.
Side exhaust
kit
part no. WTZ 1265
Note:
The maximum permitted number of 90 °
elbows (including this side exhaust kit)
is four!
I_1 Special tool for cutting the hole in
prepared side panel is required.
Contact local dealer!
Bottom
exhaust
kit
part no. WTZ 1280
The parts required for the LP version
can be obtained from your local dealer.
Please follow the installation
instructions supplied by the appropriate
manufacturer!
Note:
Dryer must be checked for proper
operation whenever the gas
connections have been broken
Left hinge kit
part no. WTZ 1260 for all dryers except
silver duo tone
part no. WTZ 126S for duo tone silver
dryers
The door catch can be reversed if
necessary. The door is hinged on the
right at the factory.
Pedestal
Mounting
Kit
part no. WTZ 1295 (White Dryers)
part. no. WTZ 1295P (Duo tone Silver)
If mounting the dryer on the pedestal
follow the instructions supplied with the
pedestal.
Exhaust
vent hood
The exhaust duct must end with an
approved exhaust vent hood with
swing out damper(s). DO NOT use an
exhaust vent hood with magnetic
latches.
To avoid exhaust restriction, the outlet
must be a minimum of 12 inches (30
cm) above ground level or any other
obstructing surface.
part no. WTZ 1270
Note:
The maximum permitted number of 90 °
elbows (including this side exhaust kit)
is four!
LP - Gas Kit