Descargar Imprimir esta página

Mitsubishi Electric TPKA0A.1LA00 Serie Manual De Instrucciones página 9

Ocultar thumbs Ver también para TPKA0A.1LA00 Serie:

Publicidad

Idiomas disponibles

Idiomas disponibles

3. Operation
3.5.2 Vane·Vent. (Lossnay)
<Accessing the menu>
Main
Main menu
Operation
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu: RETURN
Cursor
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
<Vane setting>
Fri
Off
Vane
Vent.
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Fri
83
Room
Cool
Set temp.
Auto
83
Mode
Temp.
Fan
<Vent. setting>
Fri
Low
Vent.
F1
F2
F3
F4
ON
RETURN SELECT
MENU
OFF
HOLD
Select "Operation" from the Main
menu (refer to 3.5.1), and press the
[SELECT/HOLD] button.
Select "Vane·Louver·Vent.
(Lossnay)" from the Operation
menu, and press the [SELECT/
HOLD] button.
Press the [F1] or [F2] button.
Press the button as indicated above
to go through the following setting
options.
Auto
Auto
Step 1
Step 2
Step 3
Step 4
Step 5
Swing
Swing
Select "Swing" to move the vanes
up and down automatically.
When set to "Step 1" through
"Step 5", the vane will be fixed at
the selected angle.
under the vane setting icon
This icon will appear when the vane
is set to "Step 5" and the fan oper-
ates at low speed during cooling or
drying operation (depends on the
model).
The icon will go off in an hour, and
the vane setting will automatically
change.
Press the [F4] button to go through
the ventilation setting options in the
order of "Off", "Low ", and "High".
* Settable only when LOSSNAY unit
is connected.
Off
Low
High
Off
Low
• The fan on some models of indoor
units may be interlocked with cer-
tain models of ventilation units.
<Returning to the Main menu>
Operation
Vane·Louver·Vent. (Lossnay)
High power
Comfort
Main menu: RETURN
Cursor
F1
F2
F3
RETURN SELECT
MENU
HOLD
Note:
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
1. While the display is in "Standby" or "Defrost" states.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
3. In heat mode, when room temperature is higher than the tem-
perature setting.
<[Manual] To Change the Airflow's Left/Right Direction>
* The louver button cannot be used.
• Stop the unit operation, hold the lever of the louver, and adjust to the
desired direction.
* Do not set to the inside direction when the unit is in the cooling or dry-
ing mode because there is a risk of condensation and water dripping.
Caution:
To prevent falls, maintain a stable footing when operating the unit.
3.6. Ventilation
For LOSSNAY combination
The following 2 patterns of operation is available.
• Run the ventilator together with indoor unit.
• Run the ventilator independently.
High
Press the [RETURN] button to go
back to the Main menu.
F4
ON
OFF
en
8

Publicidad

loading