Proceed with the following checks before calling the Technical Service:
Problem
The kitchen hood does
not work.
The kitchen hood does
not extract sufficiently
or vibrates.
When exterior gas extraction is not possible, then the kitchen hood may be set to purify the air by
recycling it through active charcoal filters.
The active charcoal filters have an active life of between three to six months, depending on the
individual conditions of use. These filters cannot be washed nor regenerated. They must be replaced
once their useful life comes to an end.
The manufacturer reserves the right to make changes and corrections to its products as it
deems necessary, without altering their basic characteristics.
Problem solving
Possible cause
The mains cable is not
connected to the network.
There is no current in the
network.
Filters are saturated with fat.
Obstruction in the air outlet.
Active charcoal filters (Optional)
Solution
Connect the mains cable to the
network.
Provide current to the network.
Change or clean the active
charcoal and/or metal filters.
Remove the obstruction.