10. Technical specifications
Test voltages
Maximum resistance
reading
Short circuit current
Test voltages accuracy
Equipment basic accuracy : 5% of reading ± 3 digits
Advanced features
Built-in printer
Serial data output
Built-in chronometer
Environmental protection
Safety class
Overvoltage category
E.M.C.
Electrostatic immunity
Electromagnetic irradiation
immunity
Power supply
Battery charger
Operating temperature
range
Storage temperature range : -25°C to +65°C
: 0.5 kV - 1 kV - 2.5 kV - 5 kV directly, one button
selectable. 0.5 kV to 5 kV in 500 V steps. DC,
negative.
: 5 TΩ @ 5 kV
: 1.5 ± 0.5 mA
: ± 3% of nominal test voltages @ R ≥ 10 GΩ
(1 MΩ to 500 GΩ at any test voltage)
: Automated Polarization Index computing
Automated Dielectric Absorption Ratio computing
: Prints elapsed time, actual voltage and resistance
measured each 15 seconds (offered as an optional
feature).
: RS232 @ 4800 bps. Suitable for data collection in
an external serial printer, computer or data-logger.
: Shows elapsed time in mm:ss format. Count starts
automatically for each measurement.
: IP54 (with closed lid).
: Meets the requirements of IEC 61010-1:1990,
IEC 61010-1:1992 amendment 2.
: EN 61010-1 to 600 V CAT. III
: In accordance with IEC 61326-1.
: In accordance with IEC 1000-4-2.
: In accordance with IEC 61000-4-3.
: Internal rechargeable 12 V - 2.3 Ah battery.
: 100 - 240 V~
: -5°C to +50°C