Environmental Function Control (EFC)
When started up and then every 20 ... 40 minutes the pump automatically performs a pre-pro-
grammed self-test (Environmental Function Control (EFC)). The pump detects if it is running dry
/ clogged or submerged. The pump shuts down automatically after 60 to 120 seconds if it runs
dry/is blocked. In the event of a malfunction, disconnect the power supply and "flood the pump"
or remove the obstacle. Afterwards, the unit can be restarted.
Operation
Controller overview
Description
1
Four-digit LED display
2 "On/Off" button
3 Arrow keys
4 "Mode" button
5 LED wireless connection
Speed / %
Runtime / h
Power / W
RPM
ON
Error
Function
For displaying values
• Standard display is "Power / W" mode.
For switching the pump on or off
For increasing or decreasing rotation speed/power out-
put
• For selecting the next mode
• For switching the wireless connection on/off
• The LED lights up when the wireless connection is
switched on.
• The LED blinks when connected to the OASE App.
The respective LED lights up for the mode that is se-
lected.
• The current mode appears in the display.
The LED lights up when the pump is switched on.
The LED lights up when an error occurs.
• The error code appears in the display.