Air Compressor
Pump (not shown):
Compresses
air into the air tank.
Working air is not available
until the
compressor
has raised the air tank
pressure
above that required at the air
outlet.
Check
Valve:
When the air compres-
sor is operating,
the check valve is
"open",
allowing
compressed
air to
enter the air tank.
When the air com-
pressor reaches
"cut-out"
pressure,
the check valve "closes",
allowing
air
pressure to remain inside the air tank.
Pressure
Release Valve:
The pres-
sure release valve located on the side
of the pressure switch,
is designed
to
automatically
release compressed
air
from the compressor
head and the
outlet tube when the air compressor
reaches "cut-out"
pressure or is shut
off. The pressure release valve allows
the motor to restart freely. When the
motor stops running,
air will be heard
escaping
from this valve for a few
seconds.
No air should be heard
leaking when the motor is running, or
continuous
leaking after unit reaches
"cut-out"
pressure.
How to Use Your Unit
How
to Stop
1.
Set the Auto/Off
lever to "Off".
Before
Starting
Do not operate this
unit until you read this
instruction
manual for safety, operation
and maintenance
instructions.
Break-in
Procedure
Risk of Unsafe
Operation.
Serious
damage
may result if the following
break-in
instructions
are not
closely followed.
This procedure
is required before the
air compressor
is put into service and
when the check valve or a complete
compressor
pump has been replaced.
1.
Make sure the Auto/Off
lever is in
the "Off" position.
NOTE: Pull coupler
back until it clicks
to prevent air from escaping
through
the quick connect.
2.
Plug the power cord into the
correct
branch circuit receptacle.
(Refer to Voltage
and Circuit
Protection
paragraph
in the
Installation
section
of this
manual.)
3.
Open the drain valve (counter-
clockwise)
fully to permit air to
escape and prevent
air pressure
build up in the air tank during the
break-in
period.
4.
Move the Auto/Off
lever to "Auto"
position. The compressor
will start.
5.
Run the compressor
for 15
minutes.
Make sure the drain
valve is open and there is
minimal air pressure
build-up
in
tank.
6.
After 15 minutes,
close the drain
valve by turning
clockwise.
The
air receiver will fill to "cut-out"
pressure
and the motor will stop.
The compressor
is now ready for use.
Before Each Start-Up
1.
Place Auto/Off
lever to "Off".
2.
Pull the regulator
knob out and
turn counterclockwise
to set the
outlet pressure to zero.
3.
Visually inspect air hose, replace if
needed.
4.
Attach
hose and accessories.
NOTE: The hose or accessory
will
require a quick connect
plug if the
air outlet is equipped
with a quick
connect
socket.