• The product is intended solely for use at connection
points that
a. do not exceed a maximum permissible mains im-
pedance "Z" (Zmax = 0.354 Ω), or
b. have a continuous current-carrying capacity of
the mains of at least 100 A per phase.
• As the user, you are required to ensure, in consulta-
tion with your electric power company if necessary,
that the connection point at which you wish to oper-
ate the product meets one of the two requirements,
a) or b), named above.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage
regularly. Make sure that the connection cable does
not hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H07RN".
The printing of the type designation on the connection
cable is mandatory.
For single-phase AC motors, we recommend a fuse
rating of 16A (C) or 16A (K) for machines with a high
starting current (starting from 3000 watts)!
AC motor 230 V~ / 50 Hz
Mains voltage 230 V~ / 50 Hz.
The mains connection and the extension cable have to
be three-core cables = P + N + SL. - (1/N/PE).
Extension cables must have a minimum cross-section
of 1.5 mm². Mains fuse protection is 16 A maximum.
12. Cleaning
Attention!
Pull out the power plug before carrying out any clean-
ing work on the equipment.
We recommend that you clean the equipment immedi-
ately after you use it.
Wipe swarf and dust off the machine from time to time
with a cloth.
Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these may be aggressive to the plastic parts in
the equipment. Ensure that no water can get into the
interior of the equipment.
13. Transport
For transport, the splitting knife A must be completely
moved down. Slightly tilt the log splitter with handle B
on the splitting column until the machine is inclined on
the wheels and can be moved. (Fig 11)
14. Storage
Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the device in its original packaging.
Cover the electrical tool in order to protect it from
dust and moisture. Store the operating manual with
the electrical tool.
15. Maintenance
Attention!
Pull out the power plug before carrying out any mainte-
nance work on the equipment.
When must the oil be changed
First oil change after 50 operating hours, then every
500 operating hours.
2LOFKDQJH) L J
• Completely retract the splitting column.
• Put a container with a volume of at least 6 litres un-
der the splitter.
• Release the oil dipstick 6.
• Open the oil drain plug 12a under the oil tank so the
oil can flow out.