Diagnosis de averías

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

COMPACT N&D
• Check and correct possible bad contacts on connections or terminals of the
power cable.
• Charge or replace the battery.
!
(If the error persists contact an Authorised Service Centre).
• Repair possible obstruction of the centrifugal blower or condenser fan; If the error
persists, replace the centrifugal blower or condenser fan (to access the blower or
fan it is necessary to remove the outer cover of the device, and the evaporator
cover for the centrifugal blower).
• Replace fuse 7.5A. To access the fuses of the centrifugal blower or condenser fan
you must remove the internal air distribution panel.
• Replace electronic board.
!
(If the error persists contact an Authorised Service Centre).
• Connect terminals of the control module correctly. (According to electrical
diagram attached).
• Replace electronic module/s on the compressor/s.
• Replace compressor/s.
• Check pressure (from 6 bars the compressors switch off), if necessary recover
gas and reload 330 grams per circuit.
!
To access compressors, electronic modules of compressor or charging jacks
you must remove the device's outer cover.
!
(If the error persists contact an Authorised Service Centre).