Descargar Imprimir esta página

IPC D 1814P4 T Manual De Instrucciones página 25

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
USING
THE CLEANER
CONTROL PANEL
A - On/off switch
B - Burner switch
C - Power indicator light.
D - Diesel level indicator light.
E - Fault indicator light.
F - Fault Maintenance light.
STARTING THE CLEANER
1) Turn on the water supply tap (fig. 5A).
2) Connect the water cleaner to the mains electricity supply by
plugging the plug into the socket.
3) Start the cleaner by turning the selector switch to pos. I
(fig. 7A).
!
Warning
The high pressure water jet generates a reaction force in the
lance. Keep a firm grip on the lance handle.
4) Press the trigger on the gun and begin washing.
5) To operate the water cleaner with hot water, turn the tempera-
ture regulator to the recommended washing values. (fig. 7B).
!
Warning
In water cleaners with the "Total Stop" system, the motor starts
and stops when the lever on the lance handle is actioned or
released.
!
Danger
Do not block the handle lever in the delivery position.
WARNING SIGNALS AND FAULTS DISPLAYED.
Indicator light C): Power is on when the indicator is perma-
nently alight (switch "A" in position I); when the indicator light
blinks, the appliance is in "TSI" status.
Indicator light D): Diesel level; when alight, indicates that the
level is too low. The appliance shuts down.
Indicator light E): Indicator permanently alight: 250 h sched-
uled maintenance due. Once the required maintenance has
been carried out by an IPC-approved Service Centre, the light
will extinguish.
Indicator light F): Warns when faults occur
- 2 blinks: Micro-leak alarm
- 3 blinks: alarm - no water.
- 4 blinks: alarm - motor thermal protector activated.
- 5 blinks: alarm - safety thermostat activated.
English
A A
B B
C
D
E
F
FIG. 7
23
IMPORTANT!
To eliminate any impurities
or air bubbles from the
water circuit we advise
starting the cleaner for the
first time without the lance
and letting the water run out
for a few seconds.
Impurities could block the
nozzle and cause malfunc-
tion (Fig. 8).
USING THE ACCESSO-
RIES.
The high pressure washer has
a nozzle with a flat angle jet
for cleaning large surfaces.
ROTARY HEAD (optional
accessory)
The high pressure washer
can be fitted with a head with
rotary nozzle to clean the most
stubborn dirt.
!
Danger:
Aim the jet from a certain
distance to avoid damage
caused by the high pressure.
Do not aim the jet at people,
animals or electrical sockets.
USING THE ADJUSTABLE
HEAD (Fig. 9)
To use the detergent solution,
an extension wand must be
installed, fitted with adjustable
head (supplied as an optional
accessory).
The adjustable head enables
you to select a low or high
pressure jet. The pressure is
selected by rotating the head.
High pressure pos. A. Low
pressure pos. B.
REGULATING PRESSURE.
This chapter concerns only
those models provided with
the "pressure regulating" de-
vice. The pressure regulator,
fig. 11, allows the operator to
adjust the working pressure.
When knob C is turned in
an anti-clockwise direction
(B) (minimum), the working
pressure is reduced.
FIG. 8
A
A
B
B
FIG. 9
FIG. 10
FIG.11

Publicidad

loading

Este manual también es adecuado para:

Pw-h41D1309p mD 1509p4 mD 1708p4 mD 1813p tPw-h31