man_ECO1700('20) V7.indd 107
man_ECO1700('20) V7.indd 107
The normal start-up and operating procedure is as follows:
1.
Make sure the combustion chamber is empty and clean.
2.
Make sure the stove door is closed.
3.
Fill the fuel hopper with good quality pellets.
4.
Push button 3 and hold for 2 seconds. The flue gas blower will start and the
hot rod igniter will come on. ACC will appear on the display and LED 11 will
light up to indicate that the igniter is in operation.
5.
After approx. 1 minute the display will show Load Pell. During this phase
the auger will transport the pellets from the fuel hopper to the combustion
chamber. The heat from the hot rod igniter will ignite the pellets.
6.
When the stove's required surface temperature has been reached, FIRE STAB
will appear on the display. LED 9 will go out.
7.
The recirculation fan will start running and suck air in from the space behind
the stove. This will then be blown through the heat exchanger and heated
up. The heated air is blown into the space in front of the stove.
8.
During standard operation, the display shows the heat output level (1, 2, 3,
4 or 5) and the temperature of the room.
9.
When the required room temperature has been reached, ECO and the room
temperature will appear in the display. The stove will continue to burn at its
lowest heating level. If the SAVE mode is in operation, the stove will go out
automatically when the set temperature has been reached. See section 4.6
for further explanation of the operation and setting of Save mode.
4.3 NON-STANDARD START-UP PROCEDURE
When the stove starts at a room temperature that is lower than around 0ºC or
when the combustion air is lower than 0ºC, the start-up procedure may be differ-
ent.
When the combustion procedure at these lower temperatures does not result in a
properly burning fire, the display will show "ALAr / FAN / ACC".
To light the fire, place "firelighters" on the bottom of the brazier. Light the fire-
lighter with a match and wait 1 minute before lighting the stove using the "stan-
dard start-up procedure" as described in section 4.2.
If this does not result in a properly burning fire, the stoves setup parameters will
need to be changed by a professional. Contact a Qlima-approved fitter.
4.4 SETTING THE TEMPERATURE
1.
Push button 1 to go to the temperature setting menu. The display will show
"set" and the desired temperature.
2.
Press button 1 to reduce the desired temperature. The display will show set
temperature.
4
107
30-07-20 16:47
30-07-20 16:47