Maintenance (continued)
Changing
WARNING: Drain tank to release
air pressure before removing the
oil fill cap or oil drain plug.
CAUTION: Overfilling with
oil will cause premature air
compressor failure. Do not
overfill.
1.
Remove the oil fill plug (L).
2.
Remove the oil drain plug (M) and drain
oil into a suitable container.
3.
Replace the oil drain plug (M) and
tighten securely
4.
Slowly add compressor oil until it reaches
the middle of the sight glass (N).
2
Air Filter
WARNING: Hot surfaces. Risk
of burn. Compressor heads are
exposed when filter cover is
removed. Allow compressor to
cool prior to servicing.
CAUTION: Keep the air filter
clean at all times. Do not operate
the air compressor with the air
filter removed.
A dirty air filter will not allow the air
compressor to operate at full capacity. Keep
the air filter clean at all times.
1.
Remove the air filter cover.
2.
Remove the air filter from filter cover.
4.
Place new air filter into filter cover.
5.
Replace air filter cover to pump.
NOTE: When filling the crankcase, the
oil flows very slowly into the pump. If the
oil is added too quickly, it will overflow
and appear to be full.
5.
Replace oil fill plug (L) and tighten securely.
FIGURE 6
L
N
M
3
BELT GUARD – REMOVAL
1.
Turn air compressor off, lock out
the power supply, and relieve all air
pressure from the air tank.
2.
Remove the 4 quarter turn fasteners
from the belt guard. The front belt guard
can now be lifted up and away from unit.
15
Please contact 1-888-43-HUSKY for further assistance.