2.4 Machine alarms
In case the machine fails, in this window the fault alerts are issued,
and they are the following:
SYSTEM
OK
DOOR OPEN
SYSTEM BLOCKED
HIGH PRESSURE
FAILURE
LOW PRESSURE
FAILURE
56
The machine is working correctly.
PROBABLE CAUSE
1. For safety the machine cannot work
with the door open.
Water cooled:
1. Problems with the tower cooling: it is
off, low water level, lack of maintenance
(scale).
2. Lack of water supply.
Air cooled:
1. Lack of ventilation.
2. High ambient temperature.
3. Lack of maintenance of the condenser.
4. Damaged fan.
1. The ice cream froze.
2. Gas leak.
SOLUTION
1. Close the door to continue.
(If it is closed and the alarm still appears,
contact your dealer).
Water cooled:
1. Check the cooling tower, verify that it is
turned on, filled with water, if maintenan-
ce is necessary.
2. Check the water supply.
Air cooled:
1. Place the machine in a space suitable
where you can have the correct ventilation.
2. Lower the ambient temperature to the
proper levels for the machine.
3. Check the condenser for dust.
4. Seek technical advice.
1. Remove the ice cream, wait a few
minutes for the alarm to clear.
2. If the machine does not cool down,
the ice cream does not come out with the
proper consistency and it is constantly
protected with this alarm, it is likely that
there is a gas leak, in this case it requires
technical support.