EM-40 Water
3.2.2 Recommended high and low pressure freon
• In Low pressure at the beginning of the cycle the pressure should be 45 psi and 9 psi when
lowering the temperature
• If the High Pressure exceeds 300 pounds (psi) it may mean that it is not condensing and I need
cleaning in the condenser
• The higher the pressure, the longer the ice cream production time will be.
3.2.2.1 What are the high and low freon cut out pressures at which the
sensor of each machine?
TYPE OF MACHINE
AIR
WATER
Expansion
valve
Low pressure
High pressure
Suction
accumulator
High and low
pressure switch
Oil
separator
Compressor
HIGH PRESSURE
200 - 300 PSI
350 PSI
315 PSI
Cylinder
Solenoid
valve
Peephole
Water
condenser
Filtro
deshidratador
Receiver
LOW PRESSURE
9 - 45 PSI
HIGH
Maintenance
LOW
2 PSI
2 PSI