3.2 DESCRIPTION OF TERMINALS
SE-
Pedestrian electrical lock with capacitance discharge terminals
SE+
N.O.
Normally open contact of the relay for driveway gate opener
C
Common contact of the relay for driveway gate opener
SP
Input for normally closed sensor dedicated to the DOOR STATUS function
PA
Input for pedestrian gate electric lock button
4.
WIRING INSTRUCTIONS FOR THE USE OF THE DEVICE
WITHOUT THE RJ45 ADAPTER
Remove the RJ45 adapter (13) from the POE connector (12).
Remove the insulation sheath of the CAT5/CAT5E cable (with rigid wires) for at least 40 mm.
Strip the conductors for no more than 6mm.
Insert the wires in the connector (12) respecting the positions and colour codes shown (Standard
T568B).
Pressing the orange clips on the terminal block with a screwdriver makes it easier to insert the
conductors into the terminal block.
1
Wire No.
Wire colour
1
White-Orange
2
Orange
3
White-Green
4
Connect the device to the POE switch of the system.
4.1. DISTANCES AND WIRE SECTIONS
Type of connection
LAN
Wires with cross-section area of 0.5 mm
cross section area smaller than 0.5 mm
(#) To ensure operation of the device at maximum distances, the wire must be in Category 5e and the
section of the twisted pairs must be AWG24.
The maximum resistance of the individual wires must not exceed 10ohm/100m.
The cable must be up to the following standards:
- EIA/TIA 568-B.2 o EIA/TIA 568-C.2
- EN50288 3-1
- IEC 61156-5
DS1060-193
8
Wire No.
5
6
7
Blue
8
Wire colour
White-Blue
Green
White-Brown
Brown
Max. distance
100 m
or larger must comply with IEC 60332-1-2; wires with
2
must comply with IEC 60332-2-2.
2
Min - max section
CAT5e (#)
11