5.
SPEAKER VOLUME ADJUSTMENT
For information on sound levels settings, refer to the system manual.
6.
DOOR ELECTRIC LOCK MANAGEMENT
The door units have two terminals for managing the capacitance discharge and hold of the door electric lock
(SE-, SE+). The electric lock is operated in the following cases:
•
Whenever the hall button is pressed (terminals PA).
•
When a pedestrian door opening command is received which has been sent by an indoor station
according to the configuration of the "Door secret mode" parameter (see the system technical manual").
The activation time of the electric lock can be programmed using the "Door opening time" parameter (see
see the system technical manual").
7.
GARAGE DOOR LOCK MANAGEMENT
The doors have two terminals (N.O. and C) connected to the contacts of a normally open relay which can
be used to control a gate opening control unit. The relay is operated for 3 seconds upon the receipt of the
driveway gate opening command which has been sent by an indoor station according to the configuration
of the "Gate secret mode" parameter, as for the pedestrian electric lock.
(1) The relay is not suitable to control direct power loads and can only be used as control relay.
8.
DEVICE CONFIGURATION
For the configuration of the push-button panels, download the system technical manual by scanning the
following QR Code with the camera of your smartphone or tablet.
9.
RESTART AND RESET TO FACTORY SETTINGS
To restart the device, briefly press the restart button (11) once. The LEDs (2) will flash once to confirm the
operation.
To reset the device to factory settings, proceed as follows:
1. Turn off the device by removing the power cable.
2. On the push-button panel Ref. 1060/33, press and hold: the first call button (the top button) and the hall
button.
3. On the push-button panel Ref. 1060/34, press and hold: the up arrow button and the hall button.
4. Turn on the device by connecting the power cable.
5. Do not release the buttons until the device performs the following steps in sequence: 8 flashes in
sequence of the button LEDs
- 8 flashes in sequence of the button LEDs
- Camera LEDs turning on and off.
- flashes in sequence of the button LEDs.
- Camera LEDs turning on and off.
6. Release the 2 buttons.
The reset to factory settings can be carried out also via the Ipercom Installer Tools application
(see the system technical manual).
12
DS1060-193