Descargar Imprimir esta página

Greencut EB56LI-ION Manual De Instrucciones página 48

Publicidad

Idiomas disponibles

Idiomas disponibles

48
TROUBLESHOOTING
In the event of not being able to resolve the problem, please seek technical support assistance.
POSSIBLE CAUSE
PROBLEM
- Battery not making contact.
- Battery not installed properly.
Unit does
- Battery not charged.
not run
- Battery not inserted into
charger.
- Charger not plugged in.
- Surrounding air temperature
Battery will
too hot or too cold.
not charge
STORING
Clean the blower thoroughly before storing. Store the blower in a dry, well-ventilated place that is inaccessible to
children. Keep away from corrosive agents such as garden chemicals and de-icing salts.
Store and charge your batteries in a cool area. Temperatures above or below normal room temperature will
shorten battery pack life.
Never store batteries in a discharged condition. Wait for battery pack to cool and fully charge
immediately.
All batteries gradually lose their charge. The higher the temperature, the quicker they lose their charge. If you
store your unit for long periods of time without using it, recharge the batteries every month or two. This practice
will prolong battery pack life.
Recharge batteries every 3 months
When not in use, your Cordless Blower should be stored indoors in a dry and high or locked-up place, out of reach of children.
TRANSPORTING LITHIUM BATTERIES
Transport the battery in accordance with local and national provisions and regulations.
Follow all special requirements on packaging and labelling when transporting batteries by a third party. Ensure that
no batteries can come in contact with other batteries or conductive materials while in transport by protecting exposed
connectors with insulating, non-conductive caps or tape. Do not transport batteries that are cracked or leaking. Check
with the forwarding company for further advice.
WARNING
Not intended for use other than what's listed above.
- Check battery is fully inserted.
- Check that battery is securely connected to the blower.
- Check battery charging requirements.
- Insert battery into charger until LED appears.
- Plug charger into a working outlet.
- Check current at receptacle by plugging in a lamp or other
appliance.
- Check to see if receptacle is connected to a light switch which
turns power off when you turn out the lights.
- Move charger and tool to a surrounding air temperature
of above 50 degree F (10 degree C) or below 100 degree
F ( +37.8 degree C).
SOLUTION

Publicidad

loading