Descargar Imprimir esta página

Kenmore 596.53462300 Guía Para El Uso Y Cuidado página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

YOUR
REFRIGERATOR,
e,T.
)W TO CONNECT
THE
WATER
$11PPL¥
the
MATERIALS NEEDED
> Y4" o uter diameter flexible copper
tubing
Brass compression nut and sleeve for
Y4" outer diameter copper tubing.
Shut-off valve (requires a Y4" hole to
be drilled into water supply before
valve attachment)
> Adjustable wrench
> Y4" h ex nut driver
NOTE: Add 8' to tubing length needed to
reach water supply for creation of
service loop.
1. Create service loop with tubing using
care to avoid kinks in tubing.
2. Remove plastic cap from water valve
inlet port.
4. Placeend of copper tubing into water
valve inlet port. Shape tubing slightly-
DO NOT KINK - so that tubing feeds
straight into inlet port.
5. Slide brass nut over sleeve and
screw nut into inlet port. Tighten nut
with wrench.
IMPORTANT:DO NOT overtighten.
Cross threading may occur.
6. Pull on tubing to confirm connection
is secure. Connect tubing to frame
with water tubing clamp (C) and turn
on water supply. Check for leaks and
correct, if present.
C
3. Place brass nut (A) and sleeve (B) on
copper tube end as illustrated.
A
7. Monitor water connection for 24
hours. Correct leaks, if necessary.
!/
iii
ii
/C
¸ i
10

Publicidad

loading