14
FI[T[R DATA
SYSTEM SPECIFICATION AND PERFORMANCE DATA
SHEET REFRIGERATOR WATER FILTER CARTRIDGE
MODEL 9005
Specifications
Service Flow Rate (maximum) .................................................... 0 .75 GPM (2.83 L/min)
Rated Service Life Model 9005 (maximum)................................500 gallons/1892 liters
Maximum Operating Temperature...............................................100° F/38° C
Minimum Operating Temperature................................................ 3 3 ° F/l° C
Minimum Pressure Requirement................................................. 3 5 psi/138 kPa
Maximum Operating Pressure..................................................... 1 20 psi/827 kPa
PERFORMANCE DATA
Substance
'Lead
Lead
Cyst
Turbidity
Lindane
Atrazine
Chlorine
Particulate**
2,4-D
Asbestos
Influent Challenge
Concentration
0.15 mg/L +/- 10%
0.15 mg/L +/- 10%
Minimum50,000/L
11+/-1 NTU
0.002 mg/L +/- 10%
0.009 mg/L +/- 10%
2.0 mg/L +/- 10%
at least 10,000
particles/mL
0.210 mg/L +/- 10%
107to 10Sfibers/L;fibersgreaterI
i
than !0 micrometersin length
Effluent
Average %J
Maximum
Average
Reduction
Effluent
0.001 mg/L
99.33%
0.001 mg/L
0.002 mg/L
98.66%
0.003 mg/L
lcount/mL
99.99%
3 count/mL
0.12 NTU
98.98%
0.18 NTU
0.00005 mg/L
97.62%
0.00005 mg/L
0.0002 mg/L
97.93%
0.0005 mg/L
0.09 mg/L
95.26%
0.17 mg/L
900 count/mL
99.66%
2400 count/mL
45.45 ug/L
84.42%
100 ug/L
0.16 MFL/mL
99.96%
0.16 MFL/mL
Min. Required Inlet
Reduction
pH
0.010 mg/L
6.5
0.010 mg/L
8.5
> 99.95%
NA
O.5 NTU
NA
I
0.00002 mg/L ! NA
0.003 mg/L
NA
>75%
NA
>85%
NA
0.0017 mg/L
NA
99%
NA
Tested using a flow rate of 0.75 GPM (2.83 L/rain.) and a maximum pressure of 120 psi (827 kPa)
under standard laboratory conditions, however, actual performance may vary. Health Claim
Performance tested and certified by NSF International
** Particle size range classification of test. Particles used were 0.5 -1 microns.
State
of California
Department
of Health
Sewices
Water
Treatment
Device
Certificate
Number
01 - 1486
Date
Issued:
September
21. 2001
Date
Revised:
March
20, 2O02
GENERAL USE
CONDITIONS
Read this PerformanceData Sheet and
compare the capabilities of this
refrigerator with your actual water
treatment needs.
DO NOT use this product where water
is microbiologically unsafe or of
unknown quality without adequate
disinfection installed before or after
filtration system. Systems certified
for cyst reduction may be used on
disinfected water that may contain
filterable cysts.
Use only with cold water supply.
Check for compliance with the state
and local laws and regulations.
The retractable water filtration system
uses a 9005 replacement cartridge (see
Sears contact information at the back of
your Use and Care Guide to order).
Timely replacement of filter cartridge is
essential for performance satisfaction
from this filtration system. Please refer
to the applicable section in this Use and
Care Guide for general operation,
maintenance requirements and
troubleshooting.
This system has been tested according
to ANSI/NSF 42 and 53 for reduction of
the substances listed below. The
concentrationof the indicated
substancesin water entering the system
was reducedto a concentration less than
or equal to the permissiblelimit for water
leaving the system, as specified in
ANSI/NSF 42 and 53.
wFso-wl500
wFso
500gal
WFS0-N[3CO
WFSO
300 gat
WFS0-KWlSO(
40 9005
300g_l
WFS0-KNI3CO
4_ _O05
300g_l
OWF_0-WlSO0
JVmS
5(_ _al
OWFSO-_I30a
OWF5
J_Ogal
Manuf_ctu_r: PeriL.pure {a_q,o=,=o
3he
water
z_a=ment
device,s)
IJs_
_
this certW_te
have met the tt_thtg _qui_¢nts
pbrsua_t
to Section
116830 of the
Health
_.d
Safety
Caaa for th_ foLly*tug
Ueaah _lated
_ma_n_ts:
_L_3&t,_J_
IJ_9_f.2RaSl_ei_lConl_tnan_
Cysls
Asb_
Llndan_
Tested and certified by NSF International against ANSI/NSF Standards 42 and 53 in
models WF50-KNI300 and WF50-KWl500 for the reduction of:
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Particulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane and 2, 4-D Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
@
PentaPure
INI
()_[)RAI_I)
1000 ApolloRoad
Eagan, Minnesota U.S.A.
EPAEST#35917-MN-1