Descargar Imprimir esta página

Toshiba Carrier MMY-MUP0721FT6P-UL Manual De Instalación página 7

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation space
Leave space necessary for running, installation and servicing.
Air discharge
Installation/servicing
surface
Square hole for handling
Outdoor unit height : 66.5" (1690)
0.4" (10 ) or more
1 *
1 *
L
Front side (For work and service)
*1: Please check "6 Installation of the outdoor unit" for details.
L: Recommendation 7.9" (200 mm), at least 0.8" (20 mm) or more.
Top view
NOTE
If there is an obstacle above the outdoor unit, leave a space of 78.7" (2000 mm) or more from the top of the
outdoor unit.
When the obstacle height in front side exceeds 59.1" (1500 mm), take a space of 19.7" (500 mm) or more plus half
length of the portion (H1) exceeding 59.1" (1500 mm) between the outdoor unit and the obstacle. (19.7" (500 mm)
+ H1/2)
When the obstacle height in front side exceeds 98.4" (2500 mm), the outdoor unit should be installed with at least
39.4" (1000 mm) space between the outdoor unit and the obstacle.
When the obstacle height in back side exceeds 19.7" (500 mm), take a space of 11.8" (300 mm) or more plus half
length of the portion (H2) exceeding 19.7" (500 mm) between the outdoor unit and the obstacle. (11.8" (300 mm)
+ H2/2)
When the obstacle height in back side exceeds 74.8" (1900 mm), the outdoor unit should be installed with at least
39.4" (1000 mm) space between the outdoor unit and the obstacle.
When attaching a snowfall-hood take a space for the unit height plus the snowfall-hood height.
11-EN
Air intake
Front
Back
side
side
H1
19.7" (500)+
/2
0.4" (10 ) or more
L
or more
Side view
▼ Combination of outdoor units
Model name
Ton
(Standard)
6
MMY-MUP0721F✱
8
MMY-MUP0961F✱
10
MMY-MUP1201F✱
12
MMY-MUP1441F✱
14
MMY-MUP1681F✱
16
*1
MMY-MUP1921F✱
16
MMY-UP1921F✱
18
MMY-UP2161F✱
20
MMY-UP2401F✱
22
MMY-UP2641F✱
24
MMY-UP2881F✱
26
MMY-UP3121F✱
28
MMY-UP3361F✱
Unit: in (mm)
30
MMY-UP3601F✱
32
MMY-UP3841F✱
34
MMY-UP4081F✱
36
MMY-UP4321F✱
38
MMY-UP4561F✱
40
MMY-UP4801F✱
H2
11.8" (300)+
/2
or more
42
MMY-UP5041F✱
*1 : 460 V model only lineup
Model name
Ton
(High heat)
6
MMY-MUP072H1F✱
8
MMY-MUP096H1F✱
10
MMY-MUP120H1F✱
12
MMY-UP144H1F✱
16
MMY-UP192H1F✱
20
MMY-UP240H1F✱
24
MMY-UP288H1F✱
30
MMY-UP360H1F✱
– 6 –
Unit 1
Unit 2
MMY-MUP0721F✱
-
MMY-MUP0961F✱
-
MMY-MUP1201F✱
-
MMY-MUP1441F✱
-
MMY-MUP1681F✱
-
MMY-MUP1921F✱
-
MMY-MUP0961F✱
MMY-MUP0961F✱
MMY-MUP1441F✱
MMY-MUP0721F✱
MMY-MUP1441F✱
MMY-MUP0961F✱
MMY-MUP1681F✱
MMY-MUP0961F✱
MMY-MUP1441F✱
MMY-MUP1441F✱
MMY-MUP1681F✱
MMY-MUP1441F✱
MMY-MUP1681F✱
MMY-MUP1681F✱
MMY-MUP1681F✱
MMY-MUP0961F✱
MMY-MUP1441F✱
MMY-MUP1441F✱
MMY-MUP1681F✱
MMY-MUP1441F✱
MMY-MUP1681F✱
MMY-MUP1681F✱
MMY-MUP1681F✱
MMY-MUP1441F✱
MMY-MUP1681F✱
MMY-MUP1681F✱
MMY-MUP1681F✱
MMY-MUP1681F✱
Unit 1
Unit 2
MMY-MUP072H1F✱
-
MMY-MUP096H1F✱
-
MMY-MUP120H1F✱
-
MMY-MUP072H1F✱
MMY-MUP072H1F✱
MMY-MUP096H1F✱
MMY-MUP096H1F✱
MMY-MUP120H1F✱
MMY-MUP120H1F✱
MMY-MUP096H1F✱
MMY-MUP096H1F✱
MMY-MUP120H1F✱
MMY-MUP120H1F✱
Unit 3
-
-
-
-
-
-
-
-
-
-
-
-
-
MMY-MUP0961F✱
MMY-MUP0961F✱
MMY-MUP0961F✱
MMY-MUP0961F✱
MMY-MUP1441F✱
MMY-MUP1441F✱
MMY-MUP1681F✱
Unit 3
-
-
-
-
-
-
MMY-MUP096H1F✱
MMY-MUP120H1F✱
EN
EN
ID
12-EN

Publicidad

loading