NOTE: Refer to the manufacturer's operation
manual or website for complete lists and
explanations.
• 20.03 – Source of Master Frequency
This is used to set the drive for either keypad control
or external signal input control.
• 20.04 – Source of Operation Command
This is used to set the drive to determine operating
commands from the digital keypad or external
signal inputs.
• 20.05 – Motor Rated Current
The value must be between 30 to 120% of the drive's
rated output current. This parameter sets the drive's
output current limit.
• 20.06 – Minimum Output Frequency
This parameter sets the minimum output frequency
of the AC drive. This parameter must be equal to or
less than the Mid-Point Frequency (50.7).
• 20.07 – Maximum Output Frequency
This parameter determines the AC drive's maximum
output frequency. All the AC drive accelerations
and decelerations are scaled to correspond to this
maximum output frequency.
• 20.08 – Acceleration Time
This is used to set the acceleration time. The
acceleration time is based on the time it takes for
the drive output to reach 60 Hz.
FAULT NAME
FAULT DESCRIPTION
The AC drive detects an abnormal
increase in current.
The AC drive temperature sensor
detects excessive heat.
The AC drive detects excessive drive
output current.
Internal electronic overload trip.
Motor overload.
PAGE 7 OF 24
PROGRAMMABLE FUNCTIONS
FAULT DETECTION
CORRECTIVE ACTIONS
Check the wiring connections between the AC drive and motor for
possible short circuits.
Check for excessive loading conditions at the motor.
Make sure the ambient temperature falls within the specified
temperature range.
Remove any foreign objects from the heat-sink, and check for possible
dirty heat-sink fins.
Check if the motor is overloaded.
Check for possible motor overload.
Check electronic thermal overload setting.
Reduce the motor load.
• 20.09 – Deceleration Time
This is used to set the deceleration time. The
deceleration time is based on the time it takes for
the drive output to reach zero speed (from 60 Hz)
after a stop or zero command is given.
• 50.11 – Sensorless Vector Enable
This parameter enables the sensorless vector
function. When the drive is set for sensorless vector
the starting torque will be 150% at 1Hz.
• 50.33 – Auto Restart After Fault
After a fault occurs, the AC drive can be reset/
re-started automatically up to 10 times. Setting
this parameter to 0 will disable the reset/restart
operation after any fault has occurred.
• 60.05 – DC Brake Current Level
This parameter determines the amount of DC
braking current applied to the motor during start-up
and stopping. When setting DC braking current,
please note that 100% is equal to the rated output
current of the drive.
• 60.07 – DC Braking Time upon a Stop
This parameter determines the duration of time that
the DC braking current will be applied to the motor
upon a stop command of the AC drive.
0721 IH-3704