7. CONTROL BOX
Connecting and turning on the unit
Read the General Safety Instructions before installing the operator.
Fasten the box in place using its mounting holes.
Install a switch / isolating switch on the mains in accordance with current standards.
Fasten the grommets in place and route the cables, keeping the power cables and the control cables
separate.
Connect the power and control cables by following the requirements below:
The STOP button or switch must be equipped with a manual release. Shunt the button's
terminals on the board.
Make sure all the inputs on the terminal block are wired correctly and in proper working order.
Obstacle detection (response time)
Pause time
Motor force
Learn button
P1 /SET
RESET button
0
Learn button
P2/RADIO
Jumper JP1
Removed: remote
control buttons
A or B usable
In place: remote control
buttons C or D usable
Radio
antenna
PHO- -VA-TXF Photocells
EL-S1-S2 Lighting module
Motor lag at closing
Sensitivity
Beacon
GB
9
10A fuse,
battery pack option
Backup transformer
Battery pack option
ATBT B2
Motor 1
Motor 2

Publicidad