Optional antenna
WEATAN 2
(Remove original
wire from terminal
block)
Partial opening control
(1 leaf)
EMERGENCY STOP
(button with normally closed contact)
Remove the connecting
wire from the board
Manual control
(button, door phone, etc.)
Red
Black
Doorphone or
WE8111 Bis
videophone
supplied
2 wires
Do not forget the
White
White
Alignment LED
off if
alignment
correct
shunt between
COM and GND
WEATCR 2
supplied
100 W max.
Control for lighting
the gate's path.
The following occurs if the photocell is activated:
- Movement reverses immediately during closing.
- Closure controls inhibited while gate is open.
Automatic mode is not possible if photocells are not fitted
If the red LED inside the RX portion is lit, the photocells are
aligned.
The set of photocells must be positioned 40 cm from the
bottom of a post on the non-opening side of the gate.
GB
10
IMPORTANT:
Jumper JP1 in place:
remote control buttons C
and D usable.
Jumper JP1 removed:
remote control buttons A
and B usable.
SEE DRAWING ON PAGE 11
12 V flashing beacon
No specific polarity
230 VAC protected