6
Technical data
Voltage
Current
Max. discharge hose head
Max. discharge hose lenght
Pump capacity ( discharge head 3 m)
Max. water temperature
Noise level
Weight
IP-value
7
Troubleshooting
Ensure that the power supply is switched off during repairs.
Fault
The motor runs and the cycle operates
correctly, But the water is pumped out
very slowly, or not at all.
12 V / 24 V
120 V / 230 V
The cycle runs properly but a small
amount of water remains in the bowl.
The motor makes a rattling noise.
Cycle does not run after the but-
ton is pressed.
The cycle starts but water flows too
slowly into the bowl.
Cycle starts but no water flows into the
bowl.
16
110128.11
: 12 / 24 / 120 / 230 V
: 25 / 15 / 9 / 2,8 A
: 3 m
: 30 m
: 36 liter/min @ 12 V, 43 liter/min @ 24 V, 42 liter/min @ 120/230 V
: 35˚C
: 61 dBA
: 38 kg (incl. frame)
: IP44
Possible cause
The air-relief valve does not shut properly.
The outlet pipe is blocked.
The pump housing is blocked.
The sieve is blocked.
The discharge height is too great.
The outlet pipe is blocked.
Hard object in sieve hitting the revolving
blades.
There is no power
The plug connection to the control panel
is loose
There is a fault in the control electronics
The button has not been pressed hard
enough.
The transparent hose from the button is
jammed so that the pressure switch is not
operated.
The pressure switch is faulty.
The timer is faulty.
The magnetic valve filter is blocked.
Water pressure too low.
The water supply stopcock is turned off.
Faulty magnetic valve.
Water pressure too low.
Solution
Clean the air-relief valve, or replace it.
Descale the outlet pipe.
Clean the pump housing.
Clean the sieve.
Modify the installation.
Descale the outlet.
Take motor block apart and remove object from
sieve.
Check the main switch and fuse
Repair the connection.
Replace the control electronics
Press button firmly.
Free the transparent hose.
Replace the pressure switch.
Replace timer.
Clean the filter.
Ensure minimum water pressure is 1.7 bar (25 psi).
Open the stopcock.
Replace magnetic valve.
Ensure a minimum water pressure of 1.7 bar (25 psi).