CAUTION:
Be absolutely sure to insert the nail of the
carbon brush into the contact portion
outside the brush tube. (You can insert
whichever one of the two nails provided.)
Caution must be exercised since any error
in this operation can result in the
deformed nail of the carbon brush and
may cause motor trouble at an early
stage.
6. Adjusting the base and saw blade to
maintain perpendicularity
The angle between the base and the saw
blade has been adjusted to 90°, however
should this perpendicularity be lost for
some reason, adjust in the following
manner.
(1) Turn the base face up (Fig. 29) and loosen
the wing bolt (A).
(2) Apply a square to the base and the saw
blade and, turning the slotted set screw
with a slotted-head screwdriver, shift the
position of the base to produce the desired
right angle.
7. Check for dust
Dust may be removed with a clean rag or
a cloth dampened with soapy water.
Do not use bleach, chlorine, gasoline or
thinner, for they may damage the plas-
tics.
8. Disposal of the exhausted battery
WARNING:
Do not dispose of the exhausted battery.
The battery must explode if it is
incinerated. The product that you have
purchased contains a rechargeable
battery. The battery is recyclable. At the
end of it's useful life, under various state
and local laws, it may be illegal to dispose
of this battery into the municipal waste
stream. Check with your local solid waste
officials for details in your area for
recycling options or proper disposal.
28
Nail of Carbon Brush
Fig. 27
Contact portion
outside Brush Tube
Fig. 28
Square
Slotted Set Screw
Fig. 29
Protrusion
of Carbon
Brush
Base
Wing-Bolt (A)