- Phase control relay ; you can rotate the
phase order directly in the plug without
dismantling :
- Top limit switch of the hoist (see §2.2.2)
- Lower limit switch (see §2.2.2)
Reconnect the plug and press Up or Down button.
At any time, in case of imminent danger or need,
press the Punch red button to stop any movement of
your hoist.
2.1.5 Installation of cables for lifting
Motrix 750kg 526J : Ø8.3mm
Motrix 1000kg 527B 527N and 527E :
Ø9.5mm
Motrix 1500kg 527D : Ø10.3mm 4 or 9
strands.
Our wire rope Ø10.3 5 strands must not be used
in this hoist 527D.
Use protective gloves when handling wire
rope.
Check the condition of the cable and its length
(working height + 2m).
Check the condition of the hook and safety latch.
Avoid the formation of loops when unwinding.
INSTRUCTION MANUAL
Electrical winches MOTRIX types 526&527
The end of the cable should be clean and sharp.
For your safety, use only FIXATOR cables.
Put the end stopper on the wire rope. Block with an
Allen key.
Insert the end of the wire rope through the bottom
opening A. press the UP button on the pendant
control while pushing the wire rope so that it
engages in the throat of the pulley.
When the rope come out through hole B, continue
the movement so as to obtain a sufficient length of
wire rope.