Power requirements Part 2
Power cables
•
The usable wire cross section and length depend on the power situation on
the job site.
•
General rule: The shorter and thicker the cable, the better.
•
Recommendations min. wire cross section:
- for countries with 230 volts nominal voltage: 3 x 1.5 mm
- for countries with 110 volts / 120 volts nominal voltage: 12 gauge cable
(3 x 2.5 mm
•
Use only cables appropriate for this application. Check the cables
regularly for damage.
•
Outdoors, use only extension cables approved and marked for this
purpose.
Start-up isoweld
The induction welding tool is delivered ready for operation ex-works.
The country-specific regulations must be observed.
)
2
3000
®
After opening the container, the body of the unit
can be carefully lifted out. Then the handle of the
tool (see overview) is removed from the transport
box and carefully inserted into the tool.
2.
1.
5.
4.
3.
1. Use fixing screw to secure the push-fit
connection.
2. Adjust the handle to an ergonomic
working height. For this purpose,
release the clamping lever at the upright
and adjust the height. Re-tighten the
clamping lever.
3. Connect the tool to a suitable power
source.
- the cable should not be too long
- suitable conductor cross section
- unroll extension cable
Ensure that the connection is correctly
made.
4. Operate mains switch to turn unit on.
5. The display shows the input screen.