Descargar Imprimir esta página

Mottura 1805M28B Manual De Instrucciones, Uso Y Mantenimiento página 10

Publicidad

Idiomas disponibles

Idiomas disponibles

This procedure erase the limit stops memorised in the motor.
1. Press once the "P2" button. The motor takes an up and down step and emits 1 beep.
2. Press once the "▼" button. The motor takes an up and down step and emits 1 beep
3. Press once the "P2" button. The motor takes an up and down step and emits 5 beep. The limit stops of are
erased.
This procedure reset the memory of motor. Once performed the motor returns to the first setting (no RF
Transmitters and no limit stops memorized).
1. Press once the "P2" button. The motor takes an up and down step and emits 1 beep.
2. Press once the "▬" button. The motor takes an up and down step and emits 1 beep
3. Press once the "P2" button. The motor takes an up and down step and emits 5 beep. The memory of motor
is erased.
The activation commands sent by the transmitter can be inverted by means of the movement inversion
procedure.
1. Keep for 4 sec the button on the head motor. The motor takes an up and down step and emits 1 beep.
2. Press twice the "P2" button of the trasmitter, the motor emits one beep to every pression.
3. Press once the"▼" button of the trasmitter for to turn the motor clockwise. The motor emits 3 beep. The
commands is inverted.
During this procedure the time between two commands cannot be over 10 sec. If this time is higher, the
motor automatically exits of the procedure and he recovers the parameters previously set.
This procedure erase the transmitters and limit stops memorised in the motor.
FAULT
The system does not
move
The system does not
stop at the correct
position
Batteries
Torque
Revolutions
Limit switch capacity
Radio frequency chip reception
frequency
Diameter
Protection level
Weight
Reset limit stops
Factory Reset
Inverting the movement
Troubleshooting
POSSIBLE CAUSE
Limit stops incorrectly set
Discharged batteries
R. F. association not carried
out
Faulty motor unit
Limit stops incorrectly set
Obstructions in the curtain
work space
Technical Characteristics
1805M28B
Li-Ion – 2000 mAh – 12 Vdc
1.1 Nm
40 RPM
433 MHz
25 mm
0,40 kg
4
Set the limit stops
Recharge the batteries
Carry out the association procedure
Request replacement of the motor
Set the limit stops
Remove obstructions
Li-Ion – 2600 mAh – 12 Vdc
IP30
REMEDY
unit
1805M35B
3 Nm
28 RPM
433 MHz
35 mm
IP30
1,33 kg

Publicidad

loading

Este manual también es adecuado para:

1805m35b