GCY42 Connectivity Module Installation
(sold separately)
To reduce the risk of injury
r e a d t h e o p e r a t i n g
instructions included with Bosch GCY42
connectivity module. Operating instructions
for GCY42 connectivity module include
important information not covered in this
manual.
If GCY42 connectivity module is not purchased
with the charger, or if the replacement of the
module or the battery becomes necessary,
please follow this procedure (See Fig. 2):
-
Using a flat screwdriver or a coin, remove the
cover A from the top of the unit, by turning it
1/4 turn counter-clockwise.
-
If the charger is already equipped with the
connectivity module, remove the battery B,
but do not remove the connectivity module
C.
-
If the connectivity module is installed for the
first time, remove the plastic placeholder D
from the connectivity module compartment,
and place the connectivity module C in the
compartment observing correct orientation.
Note: Store the placeholder D in a safe
place. Reinsert the placeholder again if the
communications module is removed.
-
Next place new battery B on the top of the
connectivity module with the "+" polarity
facing up.
-
Place the cover A over the battery and
turn it ¼-turn clockwise to lock using a flat
screwdriver or a coin.
Assembly
Fig. 2
7