7.2.4. Sensor specific adjustable parameters
Index Dec
Parameter Name
(Hex)
Selection of local/remote
68 (0x44)
adjustment
Process data configuration
70 (0x46)
Analogue value
1 (0x01)
Switching Output 1
2(0x02)
Switching Output 2
3 (0x03)
Switching Signal Channel 1
4 (0x04)
Switching Signal Channel 2
5 (0x05)
Dust alarm 1
6 (0x06)
Dust alarm 2
7 (0x07)
Temperature alarm
8 (0x08)
Short-circuit
9 (0x09)
Sensor Application pre-set
71 (0x47)
Temperature Alarm Threshold
72 (0x48)
High Threshold
1 (0x01)
Low Threshold
2 (0x02)
Safe ON/OFF Limits
73 (0x49)
SSC 1 - Safe limit
1 (0x01)
SSC 2 - Safe limit
2(0x02)
Event Configuration
74 (0x4A)
Maintenance (0x8C30)
1 (0x01)
Temperature fault event
2 (0x02)
(0x4000)
Temperature over-run
3 (0x03)
(0x4210)
Temperature under-run
4 (0x04)
(0x4220)
Short circuit (0x7710)
5 (0x05)
Quality of Teach
75 (0x4B)
Quality of Run
76 (0x4C)
Filter scaler
77 (0x4D)
LED indication
78 (0x4E)
Access
Default value
RW
3 = Teach-button
RW
-
RW
1 = Analogue value Active
RW
1 = Switching Output 1 Active
RW
1 = Switching Output 2 Active
RW
0 = SSC1 Inactive
RW
0 = SSC2 Inactive
RW
0 = DA1 Inactive
RW
0 = DA2 Inactive
RW
0 = TA Inactive
RW
0 = SC Inactive
R/W
0 = Full scale range
R/W
-
R/W
85°C
R/W
- 30°C
R/W
-
R/W
2 x standard hysteresis
R/W
2 x standard hysteresis
R/W
-
0 = Maintenance
R/W
Notification - Inactive
0 = Temperature fault
R/W
Error event - Inactive
0 = Temperature over-run
R/W
Warning event - Inactive
0 = Temperature under-run
R/W
Warning event - Inactive
0 = Short circuit
R/W
Error event - Inactive
RO
-
RO
-
R/W
1
R/W
1 = LED indication Active
Rev.00 - 10.2023 | CA12CA/EA/KA Capacitve sensors with IO-Link interface | © 2023 | CARLO GAVAZZI Industri
Data range
Data Type
0 = Disabled
2 = Teach-by-wire
3 = Teach-button
-
0 = Analogue value Inactive
1 = Analogue value Active
0 = Switching Output 1 Inactive
1 = Switching Output 1 Active
0 = Switching Output 2 Inactive
1 = Switching Output 2 Active
0 = SSC1 Inactive
1 = SSC1 Active
0 = SSC2 Inactive
1 = SSC2 Active
0 = DA1 Inactive
1 = DA1 Active
0 = DA2 Inactive
1 = DA2 Active
0 = TA Inactive
1 = TA Active
0 = SC Inactive
1 = SC Active
0 = Full scale range
1 = Liquid level
2 = Plastic pellets
3 = High-speed mode
-
-50...125 [°C]
-50...125 [°C]
-
0...100
0...100
-
0 = Notification event Inactive
1 = Notification event Active
0 = Error event Inactive
1 = Error event Active
0 = Warning event Inactive
1 = Warning event Active
0 = Warning event Inactive
1 = Warning event Active
0 = Error event Inactive
1 = Error event Active
0...250
0...250
1...255
0 = LED indication Inactive
1 = LED indication Active
2 = Find my sensor
Length
UintegerT
8 bit
RecordT
16 bit
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
UintegerT
8 bit
RecordT
30 bit
IntegerT
16 bit
IntegerT
16 bit
RecordT
16 bit
UintegerT
8 bit
UintegerT
8 bit
RecordT
16 bit
-
-
-
-
-
-
-
-
-
-
UintegerT
8 bit
UintegerT
8 bit
UintegerT
8 bit
BooleanT
8 bit