Electrical Connections; Useful Advice; Connecting The Motor Cables; Connecting The Control Accessories - Aprimatic BUONGIORNO Instrucciones Para La Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

4
I n s t a l l a t i o n
4.3

ELECTRICAL CONNECTIONS

!
Warning
• The operator shall always be protected upstream by a 6A automatic differential switch with 30 mA actuation
point and contact opening over 3 mm.
• The electrical installation shall be in compliance with the regulations in force in the installation country.
• Do not use intercom or phone cables.

4.3.1 Useful advice

1. For the connection to the power source use cable having a minimum cross-section of 2 x 1.5 mm
2. For the controls (open -common - close) use cables having a cross-section of 3 x 0.25 mm
5 metres; or cables having a cross-section of 3 x 0,5 mm
3. For extensions of the motor power cables, use cables having a minimum cross-section of 2 x 0.75 mm
less than 5 metres; or cables having a minimum cross-section of 2 x 1.5 mm
4. For extensions of the electric stop cables, use cables having a minimum cross-section of 2 x 0. 5 mm
less than 5 metres; or cables having a minimum cross-section of 2 x 1 mm

4.3.2 Connecting the motor cables

Double-wing
Loosen the four cross-slotted screws on the corners of the box containing the electronic card and open the cover.
Shut the two wings and check which of them rests on the other, then take the red-black wires of the corresponding
geared motor (M1) and proceed as follows:
A)- Fit the wires of geared motor (M1) that shall close last (wing above) into the cable bushing
B)- Disconnect the removable 8-pole terminal board (C2) positioned on the right in the lower part of the electronic
card and connect the red wire to terminal 6 and the black wire to terminal 7.
C)- Take the red-black cable of geared motor (M2) and, after having inserted it into the cable bushing, connect the
red wire to terminal 9 and the black wire to terminal 8 of the removable terminal board (C2).
Single-wing
For the connections of the single-wing, use only the connection to gear motor (M1).

4.3.3 Connecting the control accessories

!
Warning
The card is set only for controls with pushbutton and "man presence" logic.
Insert the cable into the cable bushing, then connect the wires to terminal board (C2) as shown in the figure.
1 = open
2 = cloe
3 = common

4.3.4 Connection to the power network

Take the power cable (not standard supplied) and insert it into the bushing of the control unit box.
Remove terminal board (C1) and connect the cable wires as follows
Blue = N / neutral
Brown/Black/Grey = L / phase
2
for lengths over 5 metres.
2
for lengths over 5 metres.
- 40 -
2
.
2
for lengths less than
2
for lengths
2
for lengths over 5 metres.
2
for lengths
R

Publicidad

Tabla de contenido