arrows to change the data on display 2 into:
a. programming of temperatures and times
CUSTOMER SETTINGS
Press
again. The displays will show the following data:
-rinsing temperature (70-95
The
arrows can be used to adjust the temperature on display 2.
Press
again. The displays will show the following data:
o
temperature (40-70
C).
The
arrows can be used to adjust the temperature on display 2.
SERVICE SETTINGS (it is recommended that they are not changed)
Press
again. The displays will show the following data:
tization temperature (50-90
The
arrows can be used to adjust the temperature on display 2.
Press
again. The displays will show the following data:
release after the activation of the pressure switch (0-40 sec.) determining the water level.
The
arrows can be used to adjust the time of water release on display 2.
Press
again. The displays will show the following data :
time (8-15 sec.).
The
arrows can be used to adjust the sanitization time on display 2.
During the setting of the above parameters the display screen is blinking, and the values of the para-
meters can be changed using the arrows.
Function Name
P1
P2
P3
P4
time for water release after the activation of the pressure switch
P5
b. programming of cycle duration
Press
Display 1 will indicate:
o
C)
o
C).
RECOMMENDED SETTINGS
Function description
sanitization (rinsing) temperature
washing temperature
minimal sanitization temperature
sanitization (rinsing) time
- 36 -
. This is the factory-set password.
- sanitization-
- washing water
- minimal sani-
time for water
Recommended value
90ºC
60ºC
82ºC
0 seconds
15 seconds
- sanitization