Descargar Imprimir esta página

cecotec BOLERO AGUAZERO 6100 FULL-BI E Manual De Instrucciones página 78

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42
ENGLISH
dishwasher is equipped with water supply and drain hoses which can be positioned on
the right or left for easy installation (depending on model).
Levelling of the device
Once the appliance has been positioned, adjust the feet (screwing them in or out) to adjust
the height of the dishwasher and level it. In any case, the apparatus must not be tilted by
more than 2°.
NOTE: the maximum height adjustment of the feet is 20 mm.
How to drain excess water from hoses
If the sink is at a 1-m height from the floor, the excess water in the drains cannot be directly
drained in the sink. You will need to empty the remaining water from the hoses in an exterior
bucket or adequate container and lower than the sink.
Water outlet
Install the drain hose. The drain hose must be correctly placed to prevent water leakage.
Make sure the water inlet hose is not twisted or crushed.
Extension hose
If you need a drain hose extension, be sure to use a similar hose.
-
It must not be longer than 4 metres; otherwise, the cleaning effect of the dishwasher may
-
be reduced.
Syphon installation
The connection must be between 50 cm (minimum) and 100 cm (maximum) above the bottom
of the dishwasher. The drain hose must be secured with a hose clamp.
Warning:
After installation, keep this manual in the printed material bags. The content of this manual is
very useful for users.
4. BEFORE USING THE DISHWASHER
Before starting the dishwasher, check the following items:
If the dishwasher is level and fixed.
-
If the inlet valve is open.
-
If there are leaks at the hose connections
-
If the cables are properly connected.
-
If there is power at the electrical outlet.
-
BOLERO AGUAZERO 6100 FULL-BI E
78

Publicidad

loading

Este manual también es adecuado para:

02783