12. DAILY OPERATION
To operate the WAVE 200 XL:
1. On the MMI, press the POOL button. The robot will start moving towards the pool, while pulling
the floating cable, and enter it and position itself on the pool floor. Make sure it straightend itself
vertically to the wall of the starting point and that the angle from the wall is less than 45°.
2. Wait for the WAVE 200 XL screens to appear. Press Start (i.e. press the two green buttons
simultaneously). The cleaning session will begin.
3. To stop the cleaning session at any time, press the right grey button on the MMI console (see the
button marked 4 in the figure on page 5).
4. Press the HOME button. The robot will start to move in the direction of the floating cable. Roll the
floating cable neatly on the cable roller using the cable roller handle. Holding the floating cable,
gently pull the robot upwards and towards the Caddy. As it reaches the side of the pool, pull the
cable gently until the floating cable handle emerges. Grasp the handle and pull the robot out of
the water. The robot will shut down automatically.
5. You can use the remote control to drive the WAVE 200 XL to the Caddy. Outside the pool, do not
pull the robot towards the Caddy by rolling up the floating cable with the cable roller handle.
6. Clean the filter as needed. When the MMI displays Filter Full, you should clean before the next
operating cycle.
Note: It is not necessary to stop the WAVE 200 XL in the middle of the cycle when the Filter Full
indicator appears. Clean the filter before the next cycle.
7. Before each operating cycle, clean the robot body, brushes and driving belt area and remove
foreign objects, rubber bands, hair, etc.
8. Once a week clean the impeller area:
Make sure the power supply is switched off and unplugged before service.
CAUTION
• Remove the four screws securing the cover of the impellers using a No. 2 Philips manual
screwdriver.
• Open and remove the cover of the impellers.
• Remove foreign objects from the impellers.
• Close the cover of the impellers and reassemble the four securing screws.
9. Make sure the floating cable is not tangled so it can be rolled up easily.
Important: Every two or three cleaning sessions, disconnect the floating cable from the
roller inner connection, unroll the entire cable and re-arrange it on the roller as required.
10. A warning message to perform Preventive Maintenance will appear on the MMI screen,
when applicable. It is obligatory that Preventive Maintenance service be performed in a
timely manner. Please contact your dealer. Failure to perform the Preventive Maintenance
service will void the warranty.
WAVE 200 XL
User Instructions
|
9