DESCRIPTION
¾
FOTO EASY:
SAFETY FUSE
SAFETY FUSE
2AT (5X20)
2A + CASE
+ CASE
FAN MOTOR
+
HEATING
ELEMENT
THERMOMETER °F
HELPFUL SUGGESTIONS
• In case of power failure for some hours during the incubation time, place one hot water bottle or similar con-
tainer into the machine and keeping the same closed. The lack of power for an extended time causes more
serious damage to eggs which are only a few days into incubation than to those which are more advanced,
when the embryo is stronger and more resilient.
• For waterfowl eggs, after 15 days of incubation, it is suggested that the eggs should be taken out of the incuba-
tor and sprayed with tepid water (using a suitable hygienic sprayer) and leave them to cool for about 15 minutes
outside the machine. This operation should be repeated every two days, till the penultimate day of incubation.
• In order to supply a constant and homogenous air flow & internal temperature, it is suggested to interchan-
ge the position of eggs between themselves weekly.
• It's recommended that the incubator is operated on an all-in/all-out system. Anyway, in case of batch set-
ting, in order to avoid conflict between the different requirements of each batch, it is suggested to proceed
as it follows:
a) During the hatching period for each cycle, add one more water basin for humidity;
b) At the end of each hatching period, take out both the basins and clean them, then re-insert one only, full
of water, two days later in order to regulate the humidity inside the machine.
• It's recommended that the incubator room should be clean and hygienic, in order to obviate any bacteriolo-
gical infection.
• It should be remembered that during incubation and hatching there is a constant risk of bacterial contami-
nation and the following precautions are therefore recommended:
- use of personal protective clothing (i.e.: disposable plastic gloves, protective respiratory mask);
- Regular cleaning and disinfection of incubation rooms;
- Careful cleaning of hands before and after the contact with organic parts using anti-bacterial gel soap.
- Avoid eating or serving food and drink in the incubation room or during the operation of the machine.
(These suggestions are extremely important in order to afford maximum protection to both eggs and operator)
12
¾
MAYA PHOTO:
SAFETY FUSE
SAFETY FUSE
2AT (5X20)
2A + CASE
+ CASE
FAN MOTOR
+
HEATING
ELEMENT
ELECTRONIC
THERMOSTAT
FOR
TEMPERATURE
REGULATION
EGG-TURNING
MOTOR
¾
INCA PHOTO:
SAFETY FUSE
SAFETY FUSE
2AT (5X20) + CASE
2A + CASE
EGG-TURNING
MOTOR
FAN MOTOR
+
HEATING
ELECTRONIC
THERMOSTAT
FOR
TEMPERATURE
REGULATION
EGG-TURNING
MOTOR
THERMOMETER °F
ELECTRONIC
THERMOSTAT
FOR
TEMPERATURE
REGULATION
THERMOMETER °F