ENGLISH
NOTE:
When cutting the plastic sheeting at the outlet, the cut should be trimmed so that it is
smooth.
4.2 Bend the connecting tubes with the port facing upwards as shown in the figure. Fig. 8
4.3 Remove the plastic cover on the tube ports and remove the protective cover on the end of
the tube connectors.
4.4 Check if there is any foreign material in the port of the connection pipe and make sure that
the port is clean.
4.5 After aligning the centre, turn the nut on the connecting pipe to tighten the nut as tight as
possible by hand.
4.6 Use a torque spanner to tighten in accordance with the values in the torque requirements
table; (refer to the torque requirements table in the INSTALLATION PRECAUTIONS section).
4.7 Wrap the joint with the insulating tube. Fig. 9
NOTE
For R32 refrigerant, the connector must be placed in the open air. Fig. 10
Fig. 7 key:
1. Tube outlet
2. Cable output
Fig. 10 key:
1. Inside
2. Exterior
3. Connectors must be in the open air
Step 5. Connect the drain hose
5.1 Adjusting the drain hose (if applicable)
In some models, both sides of the indoor unit are provided with drainage posts, you can
choose one of them to connect the drain hose. Plug the unused drain port with the rubber
plug attached to one of the ports. Fig. 11
5.2 Connect the drain hose to the drain port, make sure the gasket is tight and the sealing
effect is good.
5.3 Wrap the gasket tightly with Teflon tape to ensure that there are no leaks.
NOTE:
Make sure there are no kinks or dents, and pipes should be laid obliquely downwards to avoid
blockages to ensure proper drainage. Fig. 12