Step 3. Installation of the outdoor unit. Fig. 18
3.1 In accordance with the installation dimensions of the outdoor unit, mark the installation
position of the expansion bolts.
3.2 Drill the holes and clean the dust from the concrete and place the bolts.
3.3 If applicable, install 4 rubber blankets in the hole before attaching the outdoor unit
(optional). This will reduce vibrations and noise.
3.4 Fit the base of the outdoor unit to the pre-drilled holes and bolts.
3.5 Use a spanner to fix the outdoor unit firmly with the bolts.
NOTE:
-
The outdoor unit can be fixed on a wall mounting bracket.
-
Follow the instructions on the wall mounting bracket to fix the bracket on the wall, and
then fix the outdoor unit on it and keep it horizontal.
-
The wall mounting bracket must be able to support at least 4 times the weight of the
outdoor unit.
Step 4. Installation of the cable. Fig. 19
4.1 Use a Phillips screwdriver to unscrew the cable cover, grasp it and gently press it off.
4.2 Unscrew the cable clamp and remove it.
4.3 In accordance with the wiring diagram pasted inside the cable cover, connect the
connecting wires to the corresponding terminals and make sure that all connections are tight
and secure.
4.4 Reinstall the cable clamp and cable cover.
NOTE:
When connecting the indoor and outdoor unit cables, the power must be cut off.
Fig. 19 key:
1. Terminal block
2. Cable clamp
3. Cable cover
4. Wiring diagram
5. Outdoors
6. Power supply
7. Inside
Step 5. Connect the coolant pipe. Fig. 20
5.1 Unscrew the valve cover, grasp it and press it gently to remove it (if the valve cover is
applicable).
5.2 Remove the protective covers from the end of the valves.
5.3 Remove the plastic cover from the tube ports and check if there is any other in the
AIRCLIMA 9000 SMARTFRESH/ AIRCLIMA 12000 SMARTFRESH/ AIRCLIMA 18000 SMARTFRES/