Descargar Imprimir esta página

cecotec AIRCLIMA 9000 SMARTFRESH Manual De Instrucciones página 123

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
cylinders are used. Ensure that the correct number of cylinders is available to support
the total load of the system. All cylinders to be used are designated for the recovered
refrigerant and labelled for that refrigerant (i.e. special refrigerant recovery cylinders).
Cylinders must be completed with pressure-relief valves and associated shut-off valves
in good working order. Empty recovery cylinders are evacuated and, if possible, cooled
before recovery takes place.
-
Recovery equipment must be in good working order with a set of instructions concerning
the equipment at hand and must be suitable for the recovery of flammable refrigerants.
In addition, a set of calibrated weighing scales must be available and in good working
order. Hoses must be complete with disconnect couplings free of leakage and in good
running order. Before using the recovery machine, check that it is in good running order,
properly maintained, and that all associated electrical components are sealed to prevent
ignition in the event of refrigerant release. Consult the manufacturer in case of doubt.
-
The flammable refrigerant must be returned to the refrigerant supplier in the correct
recovery cylinder, and the applicable waste transfer note must be provided. Do not mix
refrigerants in recovery units and especially not in cylinders.
-
If compressors and compressor oils are to be removed, ensure that they have been
drained to an acceptable level so that no flammable refrigerant remains within the
lubricant. The evacuation process must be carried out before returning the compressor
to the suppliers. Only electrical heating of the compressor body should be used to
accelerate this process. When oil is drained from a system, it must be done in a safe
manner.
Maintenance
WARNINGS
When cleaning, you should turn off the air conditioner and cut off the
power supply for more than 5 minutes.
Under no circumstances should the air conditioner be rinsed with water.
Volatile liquid (e.g. thinner or petrol) will damage the air conditioner,
so use only a soft, dry cloth or a damp cloth dampened with neutral
detergent to clean the air conditioner.
Pay attention to clean the filter screen regularly to prevent it from
getting covered with dust, which will affect the effect of the filter screen.
When the operating environment is dusty, the frequency of cleaning
should be increased accordingly.
After removing the filter screen, do not touch the fins of the indoor unit
to avoid scratching.
AIRCLIMA 9000 SMARTFRESH/ AIRCLIMA 12000 SMARTFRESH/ AIRCLIMA 18000 SMARTFRES/
AIRCLIMA 24000 SMARTFRESH/ AIRCLIMA 12000 SMARTFRESH CONNECTED
ENGLISH
123

Publicidad

loading