WARNING: Keep these instructions with the product and fill in the identification sheet, entering the information
taken from the markings.
WARNING:
The periodic examination is essential to test the resistance and condition of the equipment and to
guarantee the safety of the user.
HOLE DRILLING REQUIREMENT CHART
(XX*) Minimum
(X*) Concrete thickness
distance from edge of
structures
12" (305 mm)
6" (153 mm)
5" (127 mm)
12" (305 mm)
MARKING SAMPLE :
Complies with ANSI Z359.18-2017 Type A,
OSHA 1926.502 & 1910.66, EN 795:2012 Type B
ANY ALTERATION, ABUSE OR MISUSE OF THIS
PRODUCT VOIDS THE WARRANTY.
WARNING: User using this equipment must read and
understand all instructions as failure to do so may
result in serious injury or death. Users should be
familiar with pertinent regulations governing this
equipment. All individuals who use this product must be properly
instructed on how to use the device. Void a contact with physical
hazards (thermal, chemical, electrical, etc.). Make only compatible
connections.
WARNING:
Read all safety warnings,
instructions, illustrations and specifications
provided with this product. Failure to follow all
instructions listed below may result in serious injury.
A Competent person must examine this
equipment at least once each year in strict
compliance with the instructions of the
manufacturer and the previous check must be
recorded on the attached sheet.
The frequency of inspection should be increased
in accordance with the regulations, if the
equipment is in heavy usage or if the equipment
is used in harsh environments. Also ensure that
the markings are legible.
The steel anchor should be inspected prior to each use
as per the following guidelines:
a ) Do not use if any part of the device appears to be
damaged.
10
Proper Loading Direction
CONCRETE ANCHOR
Model: DXFP845101
Serial No.:
XXXXX
Batch No.:
XXXXX
Minimum Breaking Strength: 5000 lbs.
Service Temperature: -40°F to 130°F
Material of Construction:
Cable: Galvanized Steel, Clamping Jaws: Stainless Steel
b ) Do not attempt to service the device or alter it in
any way.
D
WALT
c )
anchors should be used only with the
E
combinations of components, sub-systems
or both which may affect or interfere with
the safe function of one another. Be certain
that connecting devices are compatible and
that other elements of the PFAS are safe and
compatible before use.
d ) Always check for obstructions below the work
area to make sure that the potential fall path is
clear.
e ) Keep the equipment away from anything that
could damage it such as sharp edges, rough or
abrasive surfaces, high temperature surfaces,
heat and welding sources, moving machinery,
electrical hazards, etc.
f ) It is important to keep in mind environmental
hazards when selecting fall protection
equipment.
g ) Do not expose the equipment to chemicals,
highly corrosive or caustic environments, or to
WARNING: It is the responsibility of the users to ensure that they read, understand, and follow all instructions
and are trained in the care and use of this device. Training should be repeated periodically and any time there
is a change of components within the system. Training must be conducted without exposing the trainee to a
fall hazard.
WARNING: Do not attempt to disassemble the unit or make repairs to the equipment. Send the equipment back
to the manufacturer, or persons or entities authorized in writing by the manufacturer to make repairs to the
equipment.
WARNING:
Cleaning after use is important for maintaining the safety and life of the equipment.
Use only mild soap and water, and hang to dry in shade.
direct sunlight and UV radiation, which may
cause UV degradation.
h ) Such harmful environments require a more
frequent inspection and servicing program of
the fall protection equipment to maintain the
integrity and safety of the equipment. Contact
D
WALT
if in doubt.
E
i ) All the synthetic material of fall protection
equipment must be protected from slag, hot
sparks, open flames or other heat sources.
j ) It is recomrials are used in such applications. It
is important to allow adequate fall clearance
below the work surface.
k ) Always have a Rescue Plan ready and at hand
when using this equipment.
l ) The anchorage connector should be positioned
in such a way that minimizes the potential for
falls and the potential fall distance during use.
The complete fall protection system must be
planned (including all components, calculating
fall clearance, and swing fall) before using.
SYSTEM REQUIREMENTS:
D
WALT
Compatibility of Components:
E
Protection equipment is designed to be used
D
WALT
with
approved components. Please
E
contact
D
WALT
if you have a question regarding
E
compatibility. Making substitutions without
approval from
D
WALT
Fall Protection may lead
E
to injuries and or death by compromising the
safety and reliability of the complete system.
A Qualified person can make a determination
on compatibility of equipment from different
manufacturers.
Compatibility of Connectors: Connectors
(D-rings, hooks, carabiners) must be capable
of supporting at least 5000 lbs. (23 kN). Do not
use equipment that is not compatible. Non-
compatible connectors may unintentionally
disengage. Self-locking snap hooks and
Carabiners are required by CSA, ANSI and OSHA.
Connectors must be compatible in size, shape,
and strength.
Making Connections: Only use self-locking
D
WALT
snap hooks and carabiners with any
E
Protection equipment. Do not use equipment
that is not compatible.
NEVER use bleach or bleach solutions
to clean anchor.
MAINTENANCE, CLEANING & STORAGE:
Repairs to equipment can be made only by
a DEWALT representative or person or entity
D
WALT
D
authorized by
. Contact
E
maintenance and repair. Cleanse the equipment
of all dirt, corrosives, and contaminants.
Store the anchorage connector component in a
cool, dry and clean place out of direct sunlight.
Avoid areas where heat, moisture, light, oil, and
chemicals or their vapors or other degrading
elements may be present. Equipment which is
damaged or in need of maintenance should not
be stored in the same area as usable equipment.
Heavily soiled, wet, or otherwise contaminated
equipment should be properly maintained (e.g.
dried and cleaned) prior to storage.
Prior to using equipment which has been stored
for long periods of time, a Formal Inspection
should be performed by a Competent person.
TRAINING:
Fall
As Per OSHA: Anchorages used for attachment of
personal fall arrest systems shall be independent
of any anchorage being used to support or
suspend platforms and capable of supporting
at least 5,000 lbs. (23kN) per user attached,
or be designed, installed and used as part of a
complete PFAS which maintains a safety factor
of at least two, and is under the supervision of a
qualified person.
LIMITATION OF LIABILITY:
Irrespective of the proclaimed legal theory,
kstrong, in no event will be held liable for any
indirect, incidental, special or consequential
damages including, but not limited to, loss of
profits, in any way related to the products.
Fall
English
WALT
for
E
11

Publicidad

loading