Charging Programs and Options Combinations
1
Step
Diagnosis
Max Time
3 seconds
Voltage (V)
Current (A)
6 V Mode
Check battery
voltage
12 V Mode
Check battery
voltage
12
2
3
Recovery
Soft Start
8 hours
4 hours
Pulse charging
0,8 A charge
Increase
3,7 - 5,25 V,
until 6,0 V
voltage to 7,2 V,
5,0 A
5,0 A
Pulse charging
0,8 A charge
Increase volta-
7,5 - 10,5 V,
until 12,0 V
ge to 14,4 V,
5,0 A
5,0 A
4
5
Bulk
Absorption
Analysis
20 hours
10 hours
5 minutes
Declining
Check if voltage
current
drops to 6,2 V
7,2 V
Declining
Check if voltage
current
drops to 12,3 V
14,4 V
6
7
8
Float/Full
Maintenance
12 days
Min 6 months
6,8 V / 0,8 A
6,8 V – 7,2 V
max
0,8 A
13,6 V / 5,0 A
12,8 V – 14,4 V
max
0,8 A