TROUBLESHOOTING GUIDE
STATUS
Water flow to pressure is
too low during
Cleansing/Bidet
No water comes out
during Cleansing/Bidet
Water dripping into the
bowl when using the unit
CAUTION
Do not disassemble, repair or modify the unit
SPECIFICATIONS
CLASSIFICATION
Model No.
Back Cleansing water flow volume
Front Cleansing water flow volume
Backflow Prevention
Water Supply
Water Pressure Range
Dimensions
Weight
TO REQUEST SERVICE
• Please recheck the user's manual
• If failure or damage occurs after refering the manual,stop using the product and contact the
retailer or local service center.
760422-100 (6/23)
CAUSE
a. Low water pressure of the
unit
a. Low water pressure of water
supply
a. Water shut-off valve is
turned off/
b. Filter net of T-shaped
connector is stuck
c. Nozzle tip is stuck
d. External water pressure is
low
a. External water pressure is
too high
DESCRIPTION
8043A60G
0.4 - 1.4 L/min
0.4 - 1.4 L/min
Backflow Prevention
Direct from water pipes
Static pressure: 0.07-0.6 MPa, Dynamic pressure:above 0.05 Mpa
494 mm x 394 mm x 74 mm
2 kg
SOLUTION
a. Adjust the water pressure volume by the lever
b. Assure the nozzle tips are clean
a. Check if the water pressure is above 10 psi
b. Fully open the shut-off valve
c. Check if there are any kinks on the water
supply hose
a. Turn on the water shut-off valve
b. Clean the filter net of T-shaped connector
c. Take off and clean the nozzle tip
d. Increase external water pressure
a. The maximum water pressure of the unit is 0.6 MPa